35
DHOLLANDIA
Fasten all bolted connections to the battery, the power pack and the 100A fuse for the wheelchair lift (see below)
firmly. Loose and insufficient fitting can lead to bad contact and overheating of the connections, followed by
premature failing of the power circuit. Apply a thick layer of anti-corrosive grease or Vaseline to all electric
connections, and use protection rubbers E0289 to shield the exposed components against rain and dirt.
In an analogue way, route the 16mm² (-) earth cable from the negative pole of the vehicle battery to the earth (2) inside the
power pack. Firmly fasten the earth connection, and protect against corrosion, in the same way as the (+) battery connection.
For the wiring of the cabin switch, refer to the wiring diagram found inside the power pack and in section 9.5.
⚠
⚠