Preparing the Salt Water Solution

1. 

Make sure the AC power adapter is 
unplugged.

2. 

Remove the top cover and CEF lid.

NOTE: Only use non-iodized salt with 
the Sterilizer.

3. 

Make sure the CEF is securely in place. 
Make sure the CEF lid is turned with the 
AquaSolvo logo aligned with the control 
panel the water tank.

4. 

Using the scoop supplied with the sterilizer, 
place 2 scoops of non-iodized salt on top 
of the CEF lid as shown .

NOTE: Hard water can shorten the life of 
the Sterilizer. Water used should not have a 
hardness greater than 100ppm.

5. 

Close the top cover.

6. 

Pour fresh tap water over the CEF lid 
into the water tank until the water level 
reaches the MAX line on the water tank 
(1800ml

/

60.87oz.). Make sure all the salt is 

washed off the CEF lid.

7. 

Plug in the AC power cord to the sterilizer.

 

Figure 3. Mixing Salt Water Solution

ADD WATER

UNTIL LEVEL

REACHES

MAX LINE

AQUASOLVO

LOGO SHOULD

BE ALIGNED

WITH CONTROL

PANEL

PLACE SALT

ON THESE AREAS

POUR WATER

OVER THIS AREA 

OF CEF LID

Operating Procedures

1. 

Press the Power ON/OFF button to turn 
the Sterilizer on.  The unit will play the 
start up sound (do-re-mi) and all the 
indicators on the control panel will turn on 
for 3 seconds.

2. 

The Power ON/OFF button will be 
illuminated white, indicating that the 
sterilizer is in standby mode.

3. 

Press the power ON/OFF button again 
to begin operation. The blue light in the 
water tank will turn on, and the fan speed 
will default to level 2 fan speed and the 
HOCl disinfection indicator/button will 
illuminate,  indicating that the sterilizer is 
disinfenting bacteria and viruses from the 
air. 

4. 

Press the fan speed button to toggle 
the fan speed between sleep, 2, and 3 
speeds.  When sleep mode is selected, 
fan speed is reduced and the blue light 
inside the water tank is will turn off.

5. 

Press the power ON/OFF button again to 
turn the sterilizer OFF.

CEF Replacement

The CEF should be replaced every six months, 
or whenever indicated by the filter replacement 
indicator on the control panel.

1. 

Unplug the power cord and remove the top 
cover. The sterilizer will automatically shut 
down.

2. 

Remove the CEF lid. 

3. 

Unscrew the CEF from the tank and discard.

NOTE: Handle the new CEF by the end caps 
to avoid touching the CEF and preventing 
possible contamination of the filter element.

4. 

Remove the replacement CEF from 
packaging and screw it into the bottom of 
the water tank. Plug in the power cord.

5. 

Turn on the Sterilizer and press and hold 
HOCl air disinfection button for three 
seconds to reset the filter life timer.

Note that If you replace the filter before the 

accumulated life time is reached, the filter 

life timer cannot be reset.

To purchase replacement filters, please visit: 

www.DHLifelabs.com

Содержание AQUASOLVO AAE-30 06 Series

Страница 1: ...NUAL AAE 30XX06 www DHLifelabs com Powered by nature Delivered by science AquaSolvo HOCl technology TM XX is color code please refer to more information in page 1 MADE IN CHINA EPA Est No 99117 CHN 1...

Страница 2: ...oduct Overview 4 How It Works 5 Product Specifications 5 Unpacking and Setup 5 The Control Panel 6 Preparing the Salt Water Solution 7 Operating Procedures 8 Cold Evaporation Filter Replacement 8 Trou...

Страница 3: ...ff and moved carefully to avoid spilling the water inside If water is accidentally spilled please wipe it dry If the machine is accidentally tipped over or falls water in the tank will spill inside th...

Страница 4: ...attention Do not add any mineral waters chemicals aromatics or other liquids besides clean tap water to the water tank This can damage the Sterilizer and potentially cause a health hazard Only add ta...

Страница 5: ...st be shipped back for service 2 Remove the top cover and make sure the CEF and CEF lid are securely in place 3 Place the Sterilizer on a flat solid surface in proximity to an AC electrical outlet 4 C...

Страница 6: ...cating that the sterilizer is in standby mode 3 Press the power ON OFF button again to begin operation The blue light in the water tank will turn on and the fan speed will default to level 2 fan speed...

Страница 7: ...Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty D HLifelabs IS NOT LIABLE FOR INCIDENTAL OR CONSE QUENTIAL DAMAGES OF ANY NATURE A...

Страница 8: ......

Отзывы: