DH Instruments MFC SWITCHBOX Скачать руководство пользователя страница 9

 

1.  INTRODUCTION 

 

Page 3 

© 1997-2008 DH Instruments, a Fluke Company 

1.3.3

 

FRONT PANEL ASSEMBLY 

Provides connecting ports for up to five DUTs. 

1.3.4

 

REAR PANEL ASSEMBLY 

Supports power, signal communication with molbox1 or MFC-CB, control communication with 
molbox1 or MFC-CB and carries the cooling fan. 

1.4

 

SPECIFICATIONS 

1.4.1

 

GENERAL SPECIFICATIONS 

 

Power Requirements 

85 to 264 VAC, 50/60 Hz, 55 VA maximum consumption 

Weight

 

1.5 kg (3.25 lb) 

Dimensions 

22.5 cm W x 7.5 cm H x 20.0 D (8.85 in. x 2.95 in. x 7.87 in.) 

1.4.2

 

MFC CONTROL FUNCTION SPECIFICATIONS 

The MFC Switchbox works with any MFC that can be used with the molbox1 or MFC-CB.   
The switchbox provides the MFCs with continuous power, but the molbox1 or MFC-CB still 
provides all the control and measurement.  For detailed specifications regarding MFC control 
please refer to specifications section of the molbox1 or MFC-CB Operation and Maintenance 
Manual. 

 

 

Current based MFCs can only be used when connected to device 1 of the MFC Switchbox.   
It is not possible to switch between multiple current based MFCs. 

 

 

The Valve Test Point signal is only available on device 1 of the MFC Switchbox. 

1.4.2.1

 

MOLBOX1 OR MFC-CB MFC PORT 

Connector 

One 25 Pin Female DSUB Metal Case Socket (Back Panel) 

Signals (16) 

+15 VDC 
-15 VDC 
Power Supply Common 
Setpoint Voltage (0 to 5 VDC) 
Setpoint Common 
MFC Measure (0 to 5 VDC) 
MFC Measure Common 
Setpoint Sense (0 to 5 VDC) 

Setpoint Sense Common 
Valve Test 
Valve Test Common 
Setpoint Current (4 to 20 mA Output)
MFC Measure (4 to 20 mA Input) 
Case Ground (Earth Ground) 
RS485 TXRX+ 
RS485 TXRX- 

1.4.2.2

 

MFC PORT 1 (DEVICE 1) 

Connector 

One 25 Pin Female DSUB Metal Case Socket (Front Panel Device 1) 

Signals (16) 

+15 VDC 
-15 VDC 
Power Supply Common 
Setpoint Voltage (0 to 5 VDC) 
Setpoint Common 
MFC Measure (0 to 5 VDC) 
MFC Measure Common 

Setpoint Sense Common 
Valve Test 
Valve Test Common 
Setpoint Current (4 to 20 mA Output)
MFC Measure (4 to 20 mA Input) 
Case Ground (Earth Ground) 
RS485 TXRX+ 

Содержание MFC SWITCHBOX

Страница 1: ...1997 2008 DH Instruments a Fluke Company MFC Switchbox User s Manual...

Страница 2: ...ever no warranty expressed or implied is provided DH Instruments disclaims any responsibility or liability for any direct or indirect damages resulting from the use of the information in this manual o...

Страница 3: ...SPECIFICATIONS 3 1 4 2 MFC CONTROL FUNCTION SPECIFICATIONS 3 1 4 2 1 MOLBOX1 OR MFC CB MFC PORT 3 1 4 2 2 MFC PORT 1 DEVICE 1 3 1 4 2 3 MFC MFM PORT 2 5 DEVICE 2 DEVICE 5 4 1 4 2 4 MFC SWITCHBOX CONTR...

Страница 4: ...2008 DH Instruments a Fluke Company Page II 6 TROUBLESHOOTING 13 6 1 SYMPTOMS CAUSES SOLUTIONS 13 7 MENU TREE 15 7 1 OVERVIEW 15 7 2 MOLBOX1 OR MFC CB MFC FUNCTION KEY 15 7 3 MOLBOX1 OR MFC CB SETUP...

Страница 5: ...Page III 1997 2008 DH Instruments a Fluke Company T TA AB BL LE ES S Table 1 Troubleshooting Checklist 13 Table 2 DHI Authorized Service Providers 17 F FI IG GU UR RE ES S Figure 1 Front Panel 2 Figu...

Страница 6: ...MA AN NU UA AL L Manual Conventions CAUTION is used in throughout the manual to identify user warnings and cautions NOTE is used throughout the manual to identify operating and applications advice and...

Страница 7: ...uous power on all five devices under test DUTs The MFC Switchbox provides up to 55 watts of power This allows it to provide 260 mA per MFC when fully loaded MFCs typically require a maximum of 200 mA...

Страница 8: ...2 Rear Panel 1 3 1 3 SUBASSEMBLY DESCRIPTION 1 3 1 POWER SUPPLY Powers the electronics inside the MFC Switchbox and provides continuous power to up to five connected DUTs The switching power supply pr...

Страница 9: ...CB Operation and Maintenance Manual Current based MFCs can only be used when connected to device 1 of the MFC Switchbox It is not possible to switch between multiple current based MFCs The Valve Test...

Страница 10: ...l Signals 16 15 VDC 15 VDC Power Supply Common Setpoint Voltage 0 to 5 VDC Setpoint Common Setpoint Sense Common MFC Measure 0 to 5 VDC MFC Measure Common Setpoint Sense 0 to 5 VDC Case Ground Earth G...

Страница 11: ...INITIAL SETUP 2 3 1 POWER CONNECTION Connect the MFC Switchbox to a power source using the power cable supplied Power requirements are 85 to 264 VAC 47 to 440 Hz 55 VA maximum consumption 2 3 2 CONNE...

Страница 12: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 6 N NO OT TE ES S...

Страница 13: ...g the setup menu the MFC channel can be selected by pressing the MFC function key on the molbox1 or MFC CB front panel When the MFC function key is first pressed the screen prompts the operator to sel...

Страница 14: ...unction is activated using the MFC function key Up to 26 MFC profiles can be defined and stored MFC profiles are designed to allow the user to set up the profiles of the MFCs that are typically used w...

Страница 15: ...ts the MFC channel to use for optional MFC Switchbox mode The MFC mode v Voltage control and measure mode The selected channel will be used for voltage setting and measuring mA Current loop control an...

Страница 16: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 10 N NO OT TE ES S...

Страница 17: ...USTMENTS Page 11 1997 2008 DH Instruments a Fluke Company 5 5 M MA AI IN NT TE EN NA AN NC CE E A AN ND D A AD DJ JU US ST TM ME EN NT TS S 5 1 OVERVIEW There are no user maintainable parts or systems...

Страница 18: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 12 N NO OT TE ES S...

Страница 19: ...d The MFC Switchbox power is not on Power on the MFC Switchbox MFC connected to molbox1 doesn t appear to be responding MFC option not implemented Check to see if this option was ordered and installed...

Страница 20: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 14 N NO OT TE ES S...

Страница 21: ...s a Fluke Company 7 7 M ME EN NU U T TR RE EE E 7 1 OVERVIEW The following is the portion of the molbox1 or MFC CB internal menu that pertains to use of the MFC Switchbox 7 2 MOLBOX1 OR MFC CB MFC FUN...

Страница 22: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 16 N NO OT TE ES S...

Страница 23: ...ill even if DHI has been advised of the possibility thereof and regardless of whether such products are used individually or as components in other products Items returned to DHI under warranty claim...

Страница 24: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 18 N NO OT TE ES S...

Отзывы: