DH Instruments MFC SWITCHBOX Скачать руководство пользователя страница 2

 

 

© 1997-2008 DH Instruments, a Fluke Company 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High pressure liquids and gases are potentially hazardous.  Energy stored in these liquids and gases 
can be released unexpectedly and with extreme force.  High pressure systems should be assembled 
and operated only by personnel who have been instructed in proper safety practices. 

© 1997-2008 DH Instruments, a Fluke Company  All rights reserved. 

Information in this document is subject to change without notice.  No part of this document may be reproduced or transmitted in any 
form or by any means, electronic or mechanical, for any purpose, without the express written permission of 

DH Instruments, a 

Fluke Company  

4765 East Beautiful Lane  Phoenix  AZ  85044-5318  USA. 

DH Instruments 

makes sincere efforts to ensure accuracy and quality of its’ published materials; however, no warranty, expressed 

or implied, is provided.  

DH Instruments 

disclaims any responsibility or liability for any direct or indirect damages resulting from the 

use of the information in this manual or products described in it.  Mention of any product or brand does not constitute an 
endorsement by 

DH Instruments 

of that product or brand.  This manual was originally composed in English and was subsequently 

translated into other languages.  The fidelity of the translation cannot be guaranteed.  In case of conflict between the English version 
and other language versions, the English version predominates. 

Products described in this manual are manufactured under international patents and one or more of the following U.S. patents:  
5,142,483, 5,257,640, 5,331,838, 5,445,035.  Other U.S. and international patents pending. 

DH Instruments

DH

DHI

, MFC-CB, MFC Switchbox, molbloc and molbox1 are trademarks, registered and otherwise, of 

DH Instruments, a 

Fluke Company

 

Document No. 5500092b-01 
020604 
Printed in the USA. 

Содержание MFC SWITCHBOX

Страница 1: ...1997 2008 DH Instruments a Fluke Company MFC Switchbox User s Manual...

Страница 2: ...ever no warranty expressed or implied is provided DH Instruments disclaims any responsibility or liability for any direct or indirect damages resulting from the use of the information in this manual o...

Страница 3: ...SPECIFICATIONS 3 1 4 2 MFC CONTROL FUNCTION SPECIFICATIONS 3 1 4 2 1 MOLBOX1 OR MFC CB MFC PORT 3 1 4 2 2 MFC PORT 1 DEVICE 1 3 1 4 2 3 MFC MFM PORT 2 5 DEVICE 2 DEVICE 5 4 1 4 2 4 MFC SWITCHBOX CONTR...

Страница 4: ...2008 DH Instruments a Fluke Company Page II 6 TROUBLESHOOTING 13 6 1 SYMPTOMS CAUSES SOLUTIONS 13 7 MENU TREE 15 7 1 OVERVIEW 15 7 2 MOLBOX1 OR MFC CB MFC FUNCTION KEY 15 7 3 MOLBOX1 OR MFC CB SETUP...

Страница 5: ...Page III 1997 2008 DH Instruments a Fluke Company T TA AB BL LE ES S Table 1 Troubleshooting Checklist 13 Table 2 DHI Authorized Service Providers 17 F FI IG GU UR RE ES S Figure 1 Front Panel 2 Figu...

Страница 6: ...MA AN NU UA AL L Manual Conventions CAUTION is used in throughout the manual to identify user warnings and cautions NOTE is used throughout the manual to identify operating and applications advice and...

Страница 7: ...uous power on all five devices under test DUTs The MFC Switchbox provides up to 55 watts of power This allows it to provide 260 mA per MFC when fully loaded MFCs typically require a maximum of 200 mA...

Страница 8: ...2 Rear Panel 1 3 1 3 SUBASSEMBLY DESCRIPTION 1 3 1 POWER SUPPLY Powers the electronics inside the MFC Switchbox and provides continuous power to up to five connected DUTs The switching power supply pr...

Страница 9: ...CB Operation and Maintenance Manual Current based MFCs can only be used when connected to device 1 of the MFC Switchbox It is not possible to switch between multiple current based MFCs The Valve Test...

Страница 10: ...l Signals 16 15 VDC 15 VDC Power Supply Common Setpoint Voltage 0 to 5 VDC Setpoint Common Setpoint Sense Common MFC Measure 0 to 5 VDC MFC Measure Common Setpoint Sense 0 to 5 VDC Case Ground Earth G...

Страница 11: ...INITIAL SETUP 2 3 1 POWER CONNECTION Connect the MFC Switchbox to a power source using the power cable supplied Power requirements are 85 to 264 VAC 47 to 440 Hz 55 VA maximum consumption 2 3 2 CONNE...

Страница 12: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 6 N NO OT TE ES S...

Страница 13: ...g the setup menu the MFC channel can be selected by pressing the MFC function key on the molbox1 or MFC CB front panel When the MFC function key is first pressed the screen prompts the operator to sel...

Страница 14: ...unction is activated using the MFC function key Up to 26 MFC profiles can be defined and stored MFC profiles are designed to allow the user to set up the profiles of the MFCs that are typically used w...

Страница 15: ...ts the MFC channel to use for optional MFC Switchbox mode The MFC mode v Voltage control and measure mode The selected channel will be used for voltage setting and measuring mA Current loop control an...

Страница 16: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 10 N NO OT TE ES S...

Страница 17: ...USTMENTS Page 11 1997 2008 DH Instruments a Fluke Company 5 5 M MA AI IN NT TE EN NA AN NC CE E A AN ND D A AD DJ JU US ST TM ME EN NT TS S 5 1 OVERVIEW There are no user maintainable parts or systems...

Страница 18: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 12 N NO OT TE ES S...

Страница 19: ...d The MFC Switchbox power is not on Power on the MFC Switchbox MFC connected to molbox1 doesn t appear to be responding MFC option not implemented Check to see if this option was ordered and installed...

Страница 20: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 14 N NO OT TE ES S...

Страница 21: ...s a Fluke Company 7 7 M ME EN NU U T TR RE EE E 7 1 OVERVIEW The following is the portion of the molbox1 or MFC CB internal menu that pertains to use of the MFC Switchbox 7 2 MOLBOX1 OR MFC CB MFC FUN...

Страница 22: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 16 N NO OT TE ES S...

Страница 23: ...ill even if DHI has been advised of the possibility thereof and regardless of whether such products are used individually or as components in other products Items returned to DHI under warranty claim...

Страница 24: ...MFC SWITCHBOX USER S MANUAL 1997 2008 DH Instruments a Fluke Company Page 18 N NO OT TE ES S...

Отзывы: