PART 1 - QUICK INSTALLATION GUIDE
PRELIMINARY CHECKS
During the initial installation and maintenance, make sure that
ends of the line wires are not
live.
During the initial installation and maintenance, make sure that the system is not under
pressure
to ACCESS THE DRIVE WIRING, open the front cover as shown on p. 5
DO NOT OPEN INVERTER COVERS, except for the connector cover
Models T / T (three-phase IN / three-phase OUT) do not have the switch on board, for these
models the inverter supply line must be protected in accordance with the regulations
-
Install the inverter in a place:
o
protected from the elements
o
ventilated, free from excessive humidity or excessive dust
o
as close as possible to the pump
o
make sure that does not receive harmful vibrations or mechanical stress from connected
pipelines
-
Control panel:
1- START/STOP button
2- Red LED (power)
3- Green LED (status)
4- Display
5- SET button
6- Confirm button
7-
Scrolling UP / DOWN
/
RIGHT / LEFT
INSTALLATION AND HYDRAULIC CONNECTIONS
OUT
IN
OK
Install in a
vertical
position
NO
Do not install
in a horizontal
position
O-RING
NO SEALING
NO CANAPA
NO TEFLON
O-RING
Do not use
sealant in the
three-pieces
joint; are
already
equipped
with O-Ring
The freezing of the
liquid contained in the
inverter body causes
irreversible damage
to the inverter
1
3
4
5
6
7
2