NJL/GTECH- 3/10/06 Revision No.3
2
Detailed recommendations are contained in the current issue of the following British Standards
and Codes of Practice:-
BS 5440 Part 1
Specifications for installation of flues.
BS 5440 Part 2
Specification for installation of ventilation for gas appliances.
BS 6461 Part 1
Codes of practice for masonry chimneys and flue pipes.
BS 5871 Part 3
Decorative fuel effect gas appliances of heat input not exceeding 15kW
(2
nd
& 3
rd
family gases).
BS 6891
Specification for installation of low pressure gas pipe work of up to
28mm (R1) in domestic premises (2
nd
family gases).
BS 8303
Installation of domestic heating and cooking appliances burning solid
mineral fuels.
BS 1251
Specification for open-fireplace components.
This installation booklet must not be taken as overriding statutory requirements.
FRONT AND FRETS SUITABLE FOR ALL FIRES :
The
Renaiss
ance
range of
applianc
es can be used with a variety of fire fronts, but only if they meet the minimum ventilation
requirements shown above.
SPECIFICATIONS:
DIMENSIONS HOTBOX FIRES :
For full dimensions see Fig No.1 and table below.
D
E
C
F
G
H
H
B
A
Fig 3
Total free area in
ash pan cover
should add up to a
minimum of 4000mm2
Fig 2