background image

DFPLayer Mini

 

                                                                                               

 

0x09 

Specify playback 
source(0/1/2/3/4) 

U/TF/AUX/SLEEP/FLASH 

0x0A 

Enter into standby – low power 

loss 

 

0x0B 

Normal working 

 

0x0C 

Reset module 

 

0x0D 

Playback 

 

0x0E 

Pause 

 

0x0F 

Specify folder to playback 

1~10(need to set by user) 

0x10 

Volume adjust set 

{DH

1:Open volume adjust }{DL: set volume 

gain 0~31} 

0x11 

Repeat play 

{1:start repeat play}{0:stop play}

 

2).Query the System Parameters 

Commands 

Function Description 

Parameters(16 bit)

 

0x3C 

STAY 

 

0x3D 

STAY 

 

0x3E 

STAY 

 

0x3F 

Send initialization parameters 

0 - 0x0F(each bit represent one device of the 

low-four bits) 

0x40 

Returns an error, request 

retransmission 

 

0x41 

Reply 

 

0x42 

Query the current status 

 

0x43 

Query the current volume 

 

0x44 

Query the current EQ 

 

0x45 

Query the current playback mode 

 

0x46 

Query the current software version 

 

0x47 

Query the total number of TF card 

files 

 

0x48 

Query the total number of U-disk 

files 

 

0x49 

Query the total number of flash 

files 

 

0x4A 

Keep on 

 

0x4B 

Queries the current track of TF 

card 

 

0x4C 

Queries the current track of U-Disk 

 

0x4D 

Queries the current track of Flash 

 

3.3. Returned Data of Module

 

3.3.1. Returned Data of Module Power-on

 

1).The module power on, require a certain of the time initialization, this time is determined by U-disk, TF card, 
flash, etc. device 's file numbers, general situation in the 1.5 ~ 3Sec. If module initialization data has not been 

Содержание DFPLayer Mini

Страница 1: ...ch folder can be assigned to 1000 songs 30 levels volume adjustable 10 levels EQ adjustable 1 3 Application Car navigation voice broadcast Road transport inspectors toll stations voice prompts Railway...

Страница 2: ...ker Drive speaker less than 3W 7 GND Ground Power GND 8 SPK1 Speaker Drive speaker less than 3W 9 IO1 Trigger port 1 Short press to play previous long press to decrease volume 10 GND Ground Power GND...

Страница 3: ...VER Version Version Information Len the number of bytes after Len Checksums are not counted CMD Commands Indicate the specific operations such as play pause etc Feedback Command feedback If need for...

Страница 4: ...urns an error request retransmission 0x41 Reply 0x42 Query the current status 0x43 Query the current volume 0x44 Query the current EQ 0x45 Query the current playback mode 0x46 Query the current softwa...

Страница 5: ...xx xx EF 1 The module will enter into pause status automatically after being specified playing if customers need such application they can specify track to play the module will enter into pause statu...

Страница 6: ...6 3A 00 00 01 xx xx EF Push in TF card 7E FF 06 3A 00 00 02 xx xx EF Pull out U disk 7E FF 06 3B 00 00 01 xx xx EF Pull out TF card 7E FF 06 3B 00 00 02 xx xx EF 1 For the flexibility of the module we...

Страница 7: ...evice U disk 7E FF 06 09 00 00 01 xx xx EF xx xx Verification Specify playback device TF Card 7E FF 06 09 00 00 02 xx xx EF Specify playback device SLEEP 7E FF 06 09 00 00 05 xx xx EF 3 4 4 Specify Fi...

Страница 8: ...in strong electromagnetic interference or strong inductive capacitive load of the occasion please refer to our Notes 1 Refer diagram Figure 3 3 ad key refer 2 20 function keys allocation table Key Sh...

Страница 9: ...tracking 9 Long push always to repeat play K16 10 Repeat play tracking 10 Long push always to repeat play K17 11 Repeat play tracking 11 Long push always to repeat play K18 12 Repeat play tracking 12...

Страница 10: ...er Mini Figure 4 2 Serial Connect 5v 4 2 Other Refer Diagram Figure 4 3 headset connect module Between the headset and the module can string a 100R resistor make a limiting Figure 4 4 speaker connect...

Страница 11: ...DFPLayer Mini Figure 4 5 Ad key connect refer 5 MP3 TF 16P Size unit mm Figure 5 1 pcb size...

Страница 12: ...O using opt coupler isolation increasing TVS etc 2 ADKEY key values are in accordance with the general use of the environment if the strong inductive or capacitive load environment please note that th...

Отзывы: