www.dfi.com
17
Chapter 2 Hardware Installation
Chapter 2
JP6
1-2 On:
+12V(default)
2-3 On: +5V
JP7
1
3
2
LCD/Inverter Power Select
JP7 is used to select the power level of the LVDS LCD/inverter power connector.
1
3
2
Backlight Power Select
JP6 is used to select the power level of backlight brightness control: +3.3V or +5V.
1-2 On: +3.3V
(default)
2-3 On: +5V
1
3
2
1
3
2
Important:
Before powering-on the system, make sure that the power settings of JP6 match the
power specification of backlight control. Selecting the incorrect voltage will seriously
damage the backlight.