36
Chapter 3
BIOS SETTINGS
User's Manual |
PR610-C621
X
BMC Configuration
X
User Configuration
Configure the BMC's users in this sub-menu. The settings of all the 15 users are listed in the
lower part of the sub-menu.
X
Advanced
X
H2O IPMI Configuration
InsydeH2O Setup Utility
Rev. 5.0
F1
Help
Esc
Exit
↑/↓
Select Item
←/→
Select Item
F5/F6
Change Values
Enter
Select
X
SubMenu
F9
Setup Defaults
F10
Save and Exit
Enable/Disable IPMI Support.
Note: If changing to enable, BMC
detailed information only valid
after rebooting.
User Configuration
User ID
User Status
User Password
Channel
Privilege
Add current setting to list
-----------------------
User Id UserName
1 dfi
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Advanced
[1]
<Enabled>
[1]
<Administrator>
UserStatus Channel Privilege
Enabled
1/2/3
Admin/Admin/Admin
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
Disabled
1/2/3
N/A/N/A/N/A
User ID
There are 15 BMC users available per system. Insert a number from 1 to 15 to select which
user ID is to be configured.
User Name
Insert an alias for the currently selected user.
User Status
Enable or disable the currently selected user.
User Password
Set up a password for the currently selected user. To clear any previously configured pass-
word, press
Enter
and leave the new password empty.
Channel
Select a LAN Channel to configure the privilege of the currently selected user.
Privilege
Select among Reserved, Callback, User, Operator, Administrator, and No Access. The privilege
of a user ID can be set differently in different channels.
Add current setting to list
Save the setting of the current user ID's previlege of the current channel.
X
SDR List
X
Advanced
X
H2O IPMI Configuration
InsydeH2O Setup Utility
Rev. 5.0
F1
Help
Esc
Exit
↑/↓
Select Item
←/→
Select Item
F5/F6
Change Values
Enter
Select
X
SubMenu
F9
Setup Defaults
F10
Save and Exit
SDR List
SDR List Support
<Enabled>
ID
►
000
►
002
►
003
►
004
►
005
►
006
►
007
►
008
►
009
►
010
►
011
►
012
►
013
►
014
►
015
Advanced
SDR List Support
Enable or disable the Sensor Data Record (SDR). All recorded information is listed in the lower
part of the page.
Sensor Name
CPU Temp
PCH Temp
IO Temp
Riser Temp
3V BAT
CPU Status
CPU Missing
Physical Scrty
Voltage Fault
Pwr Unit Status
BMC Watchdog
IPMI Watchdog
SMI Timeout
System Event Log
BMC FW Health
Value
48
38
31
30
2.997
0
0
0
0
0
0
0
0
0
0
Unit
℃
℃
℃
℃
V
Discrete
Discrete
Discrete
Discrete
Discrete
Discrete
Discrete
Discrete
Discrete
Discrete