![DFE SteadyWeb Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/dfe/steadyweb/steadyweb_instruction-manual_2490682053.webp)
45
Figure 34
- TAPER RIDER OPTION CARD
a) Connect the rider roll pot. or voltage source as shown below.
Figure 35
- RIDER ROLL CONNECTIONS
Figure 36
- 10 VOLT SOURCE CONNECTIONS
b) Set the SW801 switches to select between the local taper adjustment pot. and an optional
pot. located on the controller front panel.
SW801 SWITCHES
1
2
3
4
On Taper Card
NA
NA
Open
Closed
On Front Panel
NA
NA
Closed
Open
Note:
Switches 1 and 2 are not used.