38
e) Set the SW702 (LTACH) and SW703 (RTACH) switches to accommodate the voltages measured in
step c) above. Both switches are set in exactly the same way. Use the chart below. If the machine
was run at half speed, multiply the voltages by 2 and use those values for the switch-setting chart
below.
SW702 and SW703 SWITCHES
VOLTS DC
1
2
3
4
3 - 4
Closed
Open
Open
Open
4 - 16
Open
Closed
Open
Open
16 - 64
Open
Open
Closed
Open
64 - 250
Open
Open
Open
Closed
NA = Not Applicable
Note
: Remember to use the computed, not the measured, voltage for RTACH. Multiply the
computed voltage by 2 if the machine was run at half speed.
f) Set the LTACH span pot. Run the machine at maximum speed. Measure the LTACH output
voltage at test points TP701 (+) and TP703. Adjust the LTACH Span pot. (RT701) for 10.0 volts.
g) Set the RTACH span pot. With the machine still running at maximum speed, measure the RTACH
ouput voltage at test points TP702 (+) and TP703. Adjust the RTACH Span pot. (RT702) for 10.0
volts AT THE CORE DIAMETER. As an alternate method, measure the roll diameter and adjust
the RTACH Span pot. to a voltage equal to:
10 x (core diameter)/(roll diameter).
h)
Note
: If you ran the machine at half speed, set the output voltages at 5.0 volts in steps f) and g)
above.
6.4 DIGITAL METER (See Page 6 for description)
Before using the Digital Meter, it must be adjusted to accommodate the expected maximum tension.
THIS HAS BEEN DONE AT THE FACTORY. NO CHANGES SHOULD BE NEEDED!
The calibration procedure is the same as for the analog meter. Refer to Section 4, page 18.
CAUTION:
When setting the ZERO pot. pay attention to the under-range indicator. The correct
setting is where the light just goes out as the ZERO pot. is turned clockwise.
*****
OPTIONAL PROCEDURE
*****
The range of the Digital Meter is set at the factory, and is based on the maximum tension desired by
the user. Use the following procedure to reset the range if you need to read higher tension than the
meter was originally set to read.
NOTE
: There has been a change of terminology on the circuit board from the original design. The
older terminology is in parentheses in the following procedures.
Содержание SteadyWeb
Страница 1: ...INSTRUCTION MANUAL STEADYWEB AUTOMATIC TENSION CONTROLLER DOC 801 0783...
Страница 8: ......
Страница 10: ...2 1 2 STEADYWEB CONTROLLER EXPLODED VIEW Figure 1 STEADYWEB CONTROLLER EXPLODED VIEW...
Страница 16: ...8 1 6 FRONT PANEL AND OPERATOR DEVICES Figure 2 FRONT PANEL and OPERATOR DEVICES...
Страница 20: ...12 2 3 ELECTRICAL CONNECTIONS OF OPTIONS Figure 7 ELECTRICAL CONNECTIONS OF OPTIONS...
Страница 29: ...21 5 1 THE CONTROL BOARD Figure 16 CONTROL BOARD...
Страница 30: ...22 5 2 THE POWER BOARD Figure 17 POWER BOARD...
Страница 56: ...48 Figure 39 TLS RELAY CONNECTIONS...
Страница 70: ...62 Appendix F Transducer Electrical Connections Figure 45 MODELS C RS UPB TRANSDUCER WIRING...
Страница 71: ...63 Figure 46 MODEL RFA VNW TRANSDUCER WIRING...
Страница 72: ...64 Figure 47 MODELS TR NWI TRANSDUCER WIRING...
Страница 73: ...65 Figure 48 MODEL LT TRANSDUCER WIRING...