background image

DeZURIK

  

AFR2 Filter Regulator used on  

Pneumatic Cylinder Actuators 

August 2012 

Page 3 

D10384 

Description 

The AFR2 Filter Regulator allows air pressure to be adjusted to match the requirements of the actuator 
(see the documentation envelope or IOM package supplied with your hardware for proper pressure 
settings). An internal filter traps water and other contaminants before they can cause excessive wear or 
damage to actuator components. 

Installation  

Blow out the air supply pipe to remove scale or other contaminants prior to installation. Install the 
regulator as close as possible to the instrument being supplied. For best filter drainage, position the unit 
so that the drain valve is at the lowest point on the dripwell housing. The words "IN" and "OUT" are cast 
into the body to indicate the direction of flow. 

 

 

  

The AFR2 is designed for air service only. Maximum allowable inlet pressure is 250 psi 
(1725 kPa). Operating temperatures are 0 to 160 ºF (-18 to 71 ºC). 

An internal relief circuit provides limited downstream overpressure protection, but to 
avoid exceeding outlet pressure limits while in service, a pressure relieving or pressure 
limiting device should be provided. 

Operation 

Before turning on supply air, back off the square-head adjusting screw until there is no compression of 
the range spring. After turning the supply pressure on, turn the adjusting screw clockwise to increase 
outlet pressure. 

To adjust the filter regulator, turn the adjusting screw as follows: 

1.

 

Clockwise to increase outlet pressure. 

2.  Counterclockwise to decrease outlet pressure. 

Содержание AFR2

Страница 1: ...DeZURIK Inc Sartell Minnesota USA Phone 320 259 2000 www dezurik com info dezurik com DEZURIK AFR2 FILTER REGULATOR USED ON PNEUMATIC CYLINDER ACTUATORS Instruction D10384 August 2012 ...

Страница 2: ...ion during shipment however items can be damaged in transport Carefully inspect the unit for damage upon arrival and file a claim with the carrier if damage is apparent Parts Replaceable wear parts are listed on the assembly drawing These parts can be stocked to minimize downtime Order parts from your local DeZURIK sales representative or directly from DeZURIK When ordering parts please provide th...

Страница 3: ...DeZURIK AFR2 Filter Regulator used on Pneumatic Cylinder Actuators D10384 2012 DeZURIK Inc Table of Contents Description 4 Installation 4 Operation 4 Maintenance 5 ...

Страница 4: ...in valve is at the lowest point on the dripwell housing The words IN and OUT are cast into the body to indicate the direction of flow The AFR2 is designed for air service only Maximum allowable inlet pressure is 250 psi 1725 kPa Operating temperatures are 0 to 160 ºF 18 to 71 ºC An internal relief circuit provides limited downstream overpressure protection but to avoid exceeding outlet pressure li...

Страница 5: ...id from the filter bowl slowly open the drain valve and bleed accumulated liquid 2 To clean the filter element a Shut off supply air b Drain condensed liquid c Remove four corner bolts from bottom of unit d Remove dripwell housing and filter e Clean parts and reassemble in reverse order Figure 1 Component Identification ...

Страница 6: ...ll be the only effective guarantee or warranty binding on Seller despite anything to the contrary contained in the purchase order or represented by any agent or employee of Seller in writing or otherwise notwithstanding including but not limited to implied warranties THE FOREGOING REPAIR AND REPLACEMENT LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OBLIGATIONS AND LIABILITIES INCLUDING ALL W...

Отзывы: