
DEZEGA
SKTB.02.ТСТ1.00.00.000 РЭ-U2
21
11. INSPECTION OF THE TECHNICAL CONDITION
OF THE TRAINING SELF-RESCUER
During the operation of the training self-rescuer, each disassembly and assembly, it is necessary to
check the technical condition of all components and parts for damage.
Check the tightness of the reusable air system of the training self-rescuer with a regenerative cartridge
and HME using the direct assessment method according to the diagram shown in Fig. 4, using a test
installation for breathing apparatus (DEZEGA CheckUp or similar).
DANGER!
Checking the tightness of regenerative cartridges with a reusable air system when practicing in an
unbreathable atmosphere, for example, in a «smoke chamber», is mandatory.
Fig. 4. Air system leak-tightness check
Attach mouthpiece 3 to the test installation for breathing apparatus 1 using the connection device 2.
Using the DEZEGA CheckUp in manual control mode, generate a vacuum pressure of 0.85 kPa, then
close the shut-off valve, wait for the pressure to stabilize for 30 seconds and observe the pressure drop
readings for 1 minute.
Wait for the instrument readings confirming tightness of the training self-rescuer air system (the
pressure drop shall not exceed 0.05 kPa).
In case of damage or loss of any parts or components of the training self-rescuer during the practice
exercises, they can be ordered additionally.
1. DEZEGA CheckUp
2. Connection device
3. Mouthpiece
4. Bag
5. Relief valve
6. Regenerative cartridge
Содержание TRAINER
Страница 2: ...USER MANUAL 3 INSTRUKCJA UŻYTKOWANIA 27 KULLANIM KILAVUZU 53 EN PL TR ...
Страница 3: ...TRAINER USER manual EN TRAINING SELF RESCUER ...
Страница 26: ......
Страница 27: ...TRAINER INSTRUKCJA użytkowania PL APARAT UCIECZKOWY TRENINGOWY ...
Страница 51: ......
Страница 52: ......
Страница 53: ...TRAINER KULLANIM Kilavuzu TR EĞİTİM AMAÇLI FERDİ KURTARICI ...
Страница 76: ...MS1 MUMU 112019 ...