1. SAFETY INSTRUCTIONS
The breathing apparatus must only be used for the purposes specified herein. You must fully
understand and strictly adhere to this manual.
Only trained and qualified personnel are permitted to inspect, repair and service the product as detailed
in these user manual. Further maintenance work that is not detailed in these manual for use must only
be carried out by DEZEGA or personnel qualified by DEZEGA.
CAUTION!
Only original spare parts must be used for the repair and maintenance of the breathing apparatus.
Restrictions on the use of Personal Protective Equipment
The breathing apparatus supply a gas mixture for breathing for approximately 2 hours and isolates the
user from the ambient atmosphere that may be contaminated or have a lack of oxygen for breathing.
The use of the breathing apparatus is allowed only under the following conditions:
•
the user has passed special training and is allowed to work using the breathing apparatus according
to medical indications as established;
•
the oxygen cylinder is fully filled with oxygen (with a minimum degree of purification of 99.5 %
by volume);
•
the absorption cartridge is filled with an absorber;
•
the breathing apparatus is regularly serviced and checked in accordance with this Manual;
•
the user has no beard and the mask fits tightly to the skin of the face.
NOTE!
Actual NWD for a particular user may differ from the nominal NWD due to the impact of various factors.
The actual NWD may be affected by:
•
physical fitness of the user (increased oxygen consumption);
•
the nature of work performed (active oxygen consumption);
•
emotional state of the user (an anxious or excited user can consume more oxygen);
•
the condition of breathing apparatus (poorly serviced or badly adjusted breathing apparatuses may
have a leak);
•
improperly filled absorption cartridge;
•
cylinder pressure before use (if cylinder is not filled completely).
DANGER!
In some cases, the actual NWD of the breathing apparatus may be less than 2 hours. Users who are
unfit, stressed-out, with a large build, who work in difficult conditions, as well as uninformed users or
users who do not keep the breathing apparatus in a good condition, will spend oxygen much faster.
DANGER!
The breathing apparatus is not intended for use underwater. Attempts to use breathing apparatus
underwater can cause serious injury or death.