It is possible to change the cooling element by the help of other team member. To do this, remove
the shoulder strap from the right shoulder or loose it and pull the right side of the breathing apparatus
from the back. The other team member may put the cooling element into the cooler.
In case of short short working duration (up to 10 exhalations into breathing apparatus, or up to
30 seconds of breathing in the device during checks), the breathing apparatus does not require
re-equipment and is considered ready for use. It is allowed up to 10 such short working duration
cycles (total up to 100 exhalations or 5 minutes of breathing).
NOTE!
In this case, the breathing apparatus must be used by only one user, if a change of the user is made,
then the breathing apparatus should be disinfected.
In case of work terminated before the exhaution of the oxygen in cylinder, further work using the
breathing apparatus is allowed only within 24 hours after the first donning.
Charged breathing apparatus under storage, should be checked on the
control device
once every
6 months. The breathing apparatus should be stored in accordance with conditions menstioned in
the par.14.
CAUTION!
Tests by the user with exhalations into the breathing hose system are not allowed.
The influence of high or low temperatures, as well as high or low humidity, may affect the protection
properties and duration time of the device.
When the breathing apparatus transported but not used, it should be checked by the Breathing
apparatus test set. After 30 checks without donning, it should be recharged.