Technical data
Gas alarm:
Power supply:
12 Volt DC (±10%)
mains adapter (deliv-
ered with the gas
alarm) or on-board
power supply system
Current consumption: max. 150 mA
Gas sensor:
hot-wire method
Sensitivity/alarm
threshold:
corresponds to a con-
centration of 5 % of
the relevant lower
explosive limit
Propane:
0.11 %
Butane:
0.09 %
Methane
(town gas/natural gas): 0.25 %
Alarm signal:
loud high-frequency
tone
Volume:
85 dB(A) 3m
Operating temperature: -10 °C to +50 °C
Relative air humidity: max. 95 %
Material:
ABS plastic
Dimensions:
35 x 85 x 85 m (h x w x l)
Weight:
approx. 100 g
Protection class:
III
Mains adapter (delivered with the gas
alarm):
Power supply:
230 V ~ 50 HZ
Current consumption:
max. 9 W
Current output:
12 Volt DC
max. 300 mA
Connecting cable length: approx. 2 m
Safety instructions
The following instructions are for your own
safety and satisfaction when operating the GA
607 gas alarm. Please note that non-compli-
ance with these safety instructions can lead to
a serious risk of accident.
Explanation of the symbols and terms
used:
Danger!
Failure to observe this instruc-
tion endangers life and health.
Caution!
Failure to observe this instruc-
tion poses a risk to property.
Danger!
• Do not leave small children unsupervised
with the packaging material. Danger of
suffocation.
7
IB_GA607_UK_IRL_Content.indd 7
IB_GA607_UK_IRL_Content.indd 7
20.09.2005 13:59:52 Uhr
20.09.2005 13:59:52 Uhr