background image

B2

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

-15 V

AGND

AGND

CH15+

CH14+

CH13+

CH12+

CH11+

CH10+

CH9+

CH8+

CH7+

CH6+

CH5+

CH4+

CH3+

CH2+

CH1+

CH0+

AGND

DI0/Source(0)

DI1/Gate(0)

DI2/AUX_U_D(0)

DI3/Source(1)

DI4/Gate(1)

DI5/AUX_U_D(1)

RS-485A

RS-485B

DI 6

DI 7

EXT_CLK

EXT_Trigger

EXT_CLK1

EXT_CLK2

+15 V

AGND

AGND

AGND

AGND

AGND

AGND

AGND

AGND

AGND

AISENSE2

AGND

AGND

AGND

AGND

AGND

AGND

AGND

AISENSE1

AGND

DI8/DO0

DI9/DO1

DI10/DO2

DI11/DO3

DI12/DO4

DI13/DO5

DI14/DO6

DI15/DO7

+5 V

DGND

DGND

+5 V

DGND

DGND

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

-15 V

AGND

CH. 15+

AGND

NC.

RES.*

EXT-TRIGGER

SAMPLE CLOCK

* DONT CONNECT

AGND

CH. 14+

CH. 13+

CH. 12+

CH. 11+

CH. 10+

CH. 9+

CH. 8+

CH. 7+

CH. 6+

CH. 5+

CH. 4+

CH. 3+

CH. 2+

CH. 1+

CH. 0+

NC.

NC.

NC.

NC.

NC.

RES.*

RES.*

RES.*

RES.*

NC.

+15V

AGND

CH. 15-

CH. 14-

CH. 13-

CH. 12-

CH. 11-

CH. 10-

CH. 9-

CH. 8-

CH. 7-

CH. 6-

CH. 5-

CH. 4-

CH. 3-

CH. 2-

CH. 1-

CH. 0-

AGND

NC.

NC.

NC.

NC.

NC.

NC.

NC.

DGND

DGND

+5 V

DGND

GND

AGND

NC.

+5 V

D

W7

W1

W1

W2

W3

W4

W5

W6

W7

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

PFI 14/P2.6

PFI 112/P2.4

PFI 9/P2.1

DGND

PFI 6/P1.6

PFI 5/P1.5

DGND

+5 V

DGND

PFI 1/P1.1

PFI 0/P1.0

DGND

DGND

+5 V

DGND

P0.6

P0.1

DGND

P0.4

APFI 0

AO 1

AO 0

AI 15

AI GND

AI 6

AI 13

AI GND

AI 4

AI GND

AI 3

AI 10

AI GND

AI 1

AI 8

DGND

DGND

PFI 8/P2.0

PFI 7/P1.7

PFI 15/P2.7

PFI 13/P2.5

PFI 4/P1.4

PFI 3/P1.3

PFI 2/P1.2

DGND

PFI 10/P2.2

PFI 11/P2.3

P0.3

P0.7

P0.2

DGND

P0.5

P0.0

DGND

AO GND

AO GND

AI GND

AI 7

AI 14

AI GND

AI 5

AI 12

AI Sense

AI 11

AI GND

AI 2

AI 9

AI GND

AI 0

GND

 

DGND

 

Analog OUT Ch. 1

 

Analog OUT Ch. 0

 

Internal Wiring

Analog output connector pin-assignment

68-pin high density connector

68-pin high density connector

Connector for DEWE-ORION-1616 cards

Connector for DEWE-ORION-1624 cards

Rear view

DGND 

 

 

 

16 channels single ended

 

analog output 

(output resistance 15 Ohm)

 

Please find the pin-assignment 

on the next page! 

Terminate RS-485

Connect GND to GND

P

C12 V to +V (pin 6)
Terminate RS-485

Connect chassis to GND
Connect chassis to GND
Connect chassis to GND

68-pin high density connector

Connector for National Instruments

TM

 A/D cards

16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-NI-x-U

5 = 5 V   output;  330 kHz filter

 

10 = 10 V output;  330 kHz filter

 

 

USB interface on-board

Содержание DEWE-50-USB2-16-NI

Страница 1: ...O9001 D E W E 5 0 U S B 2 1 6 N I www dewetron com T e c h n i c a l r e f e r e n c e m a n u a l A u t o m o t i v e E n e r g y P o w e r A n a l y s i s F i e l d S e r v i c e E n v i r o n m e n...

Страница 2: ...ation which is protected by copyright All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trade...

Страница 3: ...ral Information Safety Instructions 5 Warranty Information 5 Support 5 Printing History 5 Safety symbols in the manual 6 Safety instructions for all DEWETRON systems 7 Environmental Considerations 8 M...

Страница 4: ...4 Technical Reference...

Страница 5: ...TRON directly For Asia and Europe please contact For the Americas please contact DEWETRON Ges m b H Parkring 4 A 8074 Graz Grambach AUSTRIA Tel 43 316 3070 Fax 43 316 307090 Email support dewetron com...

Страница 6: ...service and repair of this product Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the...

Страница 7: ...removal unless you are qualified to do so No modifications are allowed at the instrument The fuse in the power module has to be replaced by the same type For continued protection against fire replace...

Страница 8: ...nvironmental impact of the product Product End of Life Handling Observe the following guidelines when recycling a DEWETRON system System and Components Recycling Production of these components require...

Страница 9: ...V 10 V USB interface on board Operating temperature 0 C to 50 C standard Storage temperature 20 C to 60 C Humidity operating 10 to 80 non condensing 5 to 95 rel humidity Vibration MIL STD 810F 514 5...

Страница 10: ...10 Main System...

Страница 11: ...Conversion Detailed information about the A D card are not included in this manual For detailed information see the manufacturer s A D card manual D A Conversion Detailed information about the D A ca...

Страница 12: ...A2 A D D A Conversion Notes...

Страница 13: ...oard 8 V sensor supply 9 9 V power supply The 16 slot DEWE MOTHERBOARD receives the 12 VDC power supply via a DC DC converter from the internal power supply 5 V ORION Ext CLK Ext TRIG DGND ORION Ext C...

Страница 14: ...3 W4 W5 W6 W7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65...

Страница 15: ...ctives 73 23 EEC Directive on the approximation of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits amended by the directive 93 68 EEC 89 3...

Страница 16: ...C2 Notes...

Отзывы: