background image

18

Main System

Optional conditioned signal output (option 30-OUT-5)

The conditioned signal output of each DAQP- / HSI-series module is also 

 

available on a BNC socket on the rear panel of the DEWE-30-16 as a ±5 V signal.

 

Optional conditioned signal output (option 30-OUT-10)

The conditioned signal output of each DAQP- / HSI-series module is also 

 

available on a BNC plug on the rear panel of the DEWE-30-16 as a ±10 V signal.

 

Not compatible with option 30-HSI.

5a  Optional 37-pin female SUB-D connector for option 30-16-DIFF-OUT

This connector provides 16 channel balanced differential outputs. 

 

Further information please see chapter: 

'Option 30-16-DIFF-OUT (differential output)'.

5b  Optional 37-pin female SUB-D connector for option 30-DIO-DE

This connector is for accessing the digital I/O lines of the

 

DEWE-ORION series A/D card on a 37-pin SUB-D socket.

Ground connector

For some kind of measurements, it’s necessary to give the system an additional ground connection.

Power supply input connector

This connector supports standard 100 .. 250 V

AC

 power supply input for your system.

Power-on switch

The power-on switch has to be used to switch on the system. 

Ground switch

10 

11 

12 

13 

14 

15 

16 

17 

18 

19 

20 

21 

22 

23 

24 

25 

26 

27 

28 

29 

30 

31 

32 

33 

34 

35 

36 

37 

CH 0+
CH 1+
CH 2+
CH 3+
CH 4+
CH 5+
CH 6+
CH 7+
CH 8+
CH 9+

CH 10+

CH 11+

CH 12+
CH 13+
CH 14+
CH 15+

n.c.
n.c.
n.c.

CH 0-
CH 1-
CH 2-
CH 3-
CH 4-
CH 5-
CH 6-
CH 7-
CH 8-
CH 9-
CH 10-
CH 11-
CH 12-
CH 13-
CH 14-
CH 15-
n.c.
n.c.

 

 

37-pin SUB-D connector

10 

11 

12 

13 

14 

15 

16 

17 

18 

19 

20 

21 

22 

23 

24 

25 

26 

27 

28 

29 

30 

31 

32 

33 

34 

35 

36 

37 

Bx_DO 0
Bx_DO 1
Bx_DO 2
Bx_DO 3
Bx_DO 4
Bx_DO 5
Bx_DO 6
Bx_DO 7

EXT_CLK

RS-485A

EXT_Trigger

Source Bx_CNT0

Gate Bx_CNT0

EXT_CLK2

Aux Bx_CNT0

Source Bx_CNT1

EXT_CLK1

+5 DV
+5 DV

DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
RS-485B
DGND
Gate Bx_CNT1
Aux Bx_CNT1.
-
-
RES.*
DGND
DGND

 

 

-
-
-
-
-
-
-
-
-
-
-
Bx_DI 4
Bx_DI 5
Bx_DI 6
Bx_DI 7
-
-
-

Bx_DI 8
Bx_DI 9

Bx_DI 10

Bx_DI 11

Bx_DI 12
Bx_DI 13
Bx_DI 14
Bx_DI 15

-
-
-

Bx_DI 0
Bx_DI 1

-

Bx-DI 2

Bx_DI 3

-
-
-

Digital

Input

Digital

Input

Counter

Input

Counter

Input

37-pin SUB-D connector

Содержание DEWE-30-16

Страница 1: ...ww dewetron com T e c h n i c a l r e f e r e n c e m a n u a l A u t o m o t i v e E n e r g y P o w e r A n a l y s i s A e r o s p a c e D e f e n s e T r a n s p o r t a t i o n G e n e r a l T e...

Страница 2: ...ation which is protected by copyright All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trade...

Страница 3: ...s guide includes important startup notes as well as safety notes and information about keeping your DEWETRON system in good working condition over time We strongly suggest that you read this entire ma...

Страница 4: ...4 Preface Notes...

Страница 5: ...anual 9 General safety and hazard warnings for all DEWETRON systems 10 Windows updates and antivirus security software 13 Problematic network stacks 13 Environmental Considerations 13 First steps 14 M...

Страница 6: ...6 Table of content...

Страница 7: ...ibration reports from our calibration system are available for purchase with each order We retain them for at least one year so calibration reports can be purchased for up to one year after your syste...

Страница 8: ...ocument or the use of the information in this document Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your lo...

Страница 9: ...be observed during all phases of operation service and repair of this product Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of...

Страница 10: ...a plug Please note the characteristics and indicators on the system to avoid fire or electric shocks Before connecting the system please carefully read the corresponding specifications in the product...

Страница 11: ...ring operation Make sure there is adequate ventilation Ventilation slots must not covered Only fuses of the specified type and nominal current may be used The use of patched fuses is prohibited Preven...

Страница 12: ...ces and warnings in this manual EN 61326 3 1 2008 IEC 61326 1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications intended to perform safety functions...

Страница 13: ...interfere with the primary function of the DEWETRON system to record data Therefore we recommend strongly against the installation of IT MIS software and running their processes on any DEWETRON data a...

Страница 14: ...14 1 2 3 4 First steps Power on your system Connect your sensors to the system Run DEWESoft usually via Start Programs Dewetron DEWESoft x x DEWESoft x x Start recording your data First steps...

Страница 15: ...z no bandwidth limitation 1 MHz Digital I O option 30 DIO DE option 30 DIO NI SUB D 37 socket for accessing the digital I O lines of DEWE ORION card SUB D 37 socket for accessing the digital I O lines...

Страница 16: ...ce is used for the signal interface Cabling A DE C03xx cable is used to connect the DEWE 30 16 to DEWE ORION 16xx A D cards Note xx specifies cablelength 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1...

Страница 17: ...ard 68 pin high density female type with 0 05 inch pin distance is used for the signal interface Cabling A DE C58xx cable is used to connect the DEWE 30 16 to NI 622x and NI 625x A D cards Note xx spe...

Страница 18: ...nal ground connection 7 Power supply input connector This connector supports standard 100 250 VAC power supply input for your system 8 Power on switch The power on switch has to be used to switch on t...

Страница 19: ...laces 68 pin female SUB D with 37 pin female SUB D connector Specifications 30 16 DIFF OUT Output range 5 V 2 5 V referenced to GND Output configuration Balanced differential Output impedance 1Ohm Out...

Страница 20: ...e data acquisition unit differential input amplifiers are needed The shield of the cable have to be connected to the GND pin of the 37 pin female SUB D connector of the DEWE 30 xx In usual system conf...

Страница 21: ...5 Vpp and 100 kHz is already around 30 mA The maximum output current of the 30 16 DIFF OUT is specified with 60 mA If the signal frequency increase or the cable is longer it is possible to get out of...

Страница 22: ...If a signal is connected to CFB SYNC IN the SYNC LED is turned on The DAQP CFB connectors replace the standard RS 485 In Out sockets Pin assignment of 15 pin female SUB D connector CFB SYNC IN CFB SY...

Страница 23: ...Technical Reference Manual Printing version 1 1 1 April 5 2011 Bandwidth Standard DEWE 30 16 configuration 300 kHz standard no bandwidth limitation with 30 HSI option HSI ready by option 30 HSI DEWE...

Страница 24: ...A DAQP FREQ A Already phased out models which are also not supported if 30 HSI option is installed DAQN THERM DAQN RTD DAQN OHM DAQN POT DAQN BRIDGE DAQP BRIDGE B DAQP V B x DAQP V A x DAQP TRQ DAQP V...

Страница 25: ...D Conversion Please find information about the A D conversion in the attached DEWE ORION series manual The latest version of the manual can be downloaded from http download dewetron com dl components...

Страница 26: ...A2 A D D A Conversion Notes...

Страница 27: ...8 V sensor supply 9 9 V power supply The 16 slot DEWE MOTHERBOARD receives the 12 VDC power supply via a DC DC converter from the internal power supply 5 V ORION Ext CLK Ext TRIG DGND ORION Ext CLK 2...

Страница 28: ...3 W4 W5 W6 W7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65...

Страница 29: ...he regulations of the following EC directives 73 23 EEC Directive on the approximation of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits...

Страница 30: ...C2 Notes...

Отзывы: