DEWESOFT DS-CAN2 Скачать руководство пользователя страница 4

DS-CAN2 

TECHNICAL REFERENCE MANUAL 

 

 

3. Specifications 

 

 
 
 

DS-CAN2 V20-2

4/17   

 

DS-CAN2 

SIRIUSim-4xCAN 

SIRIUSi-8xCAN 

SIRIUSif-8xCAN  SIRIUSiw-8xCAN 

CAN specification 

 

 

 

 

 

Number of ports 

8 + 1 

8 + 1 

8 + 1 

Interface type 

CAN 2.0B 

CAN 2.0B 

CAN 2.0B 

CAN 2.0B 

CAN 2.0B 

Interface data rate 

up to 1 Mbit/sec 

up to 1 Mbit/sec 

up to 1 Mbit/sec 

up to 1 Mbit/sec 

up to 1 Mbit/sec 

Special protocols 

OBDII, J1939, CAN 

out 

OBDII, J1939, CAN out 

OBDII, J1939, CAN 

out 

OBDII, J1939, 

CAN out 

OBDII, J1939, CAN 

out 

Sampling rate 

> 10 kHz per channel 

Software selectable 

> 10 kHz per channel 

Software selectable 

> 10 kHz per channel 

Software selectable 

> 10 kHz per 

channel 

Software 

selectable 

> 10 kHz per 

channel 

Software 

selectable 

Galvanic isolation 
(Sensor supply not 
isolated) 

Isolated 

Isolated 

Isolated 

Isolated 

Isolated 

Bus pin fault 
protection 

±36 V 

±36 V 

±36 V 

±36 V 

±36 V 

Power specification 

Power supply 

6 - 36 V DC 

Startup voltage 7V 

Max voltage 5.00 ±0.25 V 

2x USB 2.0 powered 

9 - 36 V DC 

9 - 36 V DC 

9 - 36 V DC 

Maximum sensor 
power 
consumption

 

3 W max total 

(max 2W on 15V) 

2.5 W max 

1 W per channel 

1 W per channel 

 

Maximum power 
consumption

 

5.5 W 

5 W 

Combined device & sensor 

consumption 

6.5 W (instrument) + 

8 W (sensor) 

6.5 W 

(instrument) + 8 

W (sensor) 

 

Environmental specification 

Interface 

USB 2.0 

USB 2.0 

USB 2.0 

USB 2.0 

USB 2.0 

Connector type  

9 pin D-SUB 

9 pin D-SUB 

9 pin D-SUB 

9 pin D-SUB 

9 pin D-SUB 

Physical 
dimensions

 

105 x 90 x 30 mm 

3.94 x 3.54 x 1.18 inch 

145 x 139 x 64mm 

5.71 x 5.43 x 2.52 inch 

266x139x64mm 

10.47 x 5.43 x 2.52 

inch 

266x139x64mm 

10.47 x 5.43 x 2.52 

inch 

282 x 135 x 70 mm 

11.10 x 5.47 x 2.76 

inch 

Weight 

Weight 230 g 

0.51 lbs 

Weight 800 g 

1.76 lbs 

1320 g 

2.90 lbs 

1320 g 

2.90 lbs 

1930 g 

4.25 lbs 

Operating 
temperature

 

-20°C to +60°C 

-10°C to +50°C 

-10°C to +50°C 

-10°C to +50°C 

-40°C to +60°C 

Storage 
temperature

 

-40°C to +70°C 

-40°C to +70°C 

-40°C to 

+70°C 

-40°C to 

+70°C 

-40°C to 

+70°C 

Humidity 

95% RH non 

condensing @ 60°C 

95% RH non condensing 

@ 60°C 

95% RH non 

condensing @ 60°C 

95% RH non 

condensing @ 

60°C 

 

IP protection 

IP50 

IP65 / IP67 

Содержание DS-CAN2

Страница 1: ...DS CAN2 TECHNICAL REFERENCE MANUAL DS CAN2 V20 2 1...

Страница 2: ...ction 8 6 Firmware upgrade 9 7 DewesoftX license information 9 8 Warranty information 11 8 1 Calibration 11 8 2 Support 11 8 3 Service repair 11 8 4 Restricted Rights 11 8 5 Printing History 12 8 6 Co...

Страница 3: ...bols and formats will be used throughout the document Important It gives you important information about the subject Please read carefully Hint It gives you a hint or provides additional information a...

Страница 4: ...voltage 5 00 0 25 V 2x USB 2 0 powered 9 36 V DC 9 36 V DC 9 36 V DC Maximum sensor power consumption 3 W max total max 2W on 15V 2 5 W max 1 W per channel 1 W per channel Maximum power consumption 5...

Страница 5: ...DS CAN2 TECHNICAL REFERENCE MANUAL 4 Device operation 4 1 Front and back side Front connectors Image 1 Front connectors Back connectors Image 2 Back connectors DS CAN2 V20 2 5 17...

Страница 6: ...J 1B 302CLLD42Z DS CAN2 V20 2 6 17 CAN connector pin out DSUB 9 male Pin Name Description 1 5V 5 V supply max current 500 mA 2 CAN_LOW CAN low 3 DGND Digital Ground 4 RES Reserved 5 RES Reserved 6 DGN...

Страница 7: ...t power supply is not needed unless you want to power external devices from DS CAN2 like CPAD2 module Then make sure that the device is connected to the PC when starting up DewesoftX The device will b...

Страница 8: ...he CAN port settings Default baud rate Operation mode CAN plugin Image 4 Adjusting CAN settings 5 2 Losing USB connection When acquiring data and the USB connection is lost the acquisition will stop I...

Страница 9: ...wesoftX license information DS CAN2 or any other Dewesoft device already comes with an embedded Dewesoft license You can check the license details with all the available options in the Licensing tab b...

Страница 10: ...REFERENCE MANUAL Image 7 Licensing options Hint All licenses regarding Krypton will only work when the Krypton system is connected to your PC and the device has been activated in the hardware setup DS...

Страница 11: ...needs to be calibrated at regular intervals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed cal...

Страница 12: ...owners 8 7 Trademarks We take pride in our products and we take care that all key products and technologies are registered as trademarks all over the world The Dewesoft name is a registered trademark...

Страница 13: ...quirements All accessories shown in this document are available as an option and will not be shipped as standard parts 10 2 1 Environmental Considerations Information about the environmental impact of...

Страница 14: ...having a protective earth terminal a non interruptible safety earth ground must be provided from the main power source to the product input wiring terminals Please note the characteristics and indica...

Страница 15: ...ng leads integrated circuits and so on are dry DO NOT use the system in rooms with flammable gases fumes or dust or in adverse environmental conditions Avoid operation in the immediate vicinity of hig...

Страница 16: ...ons in IEC 61000 6 2 or defined in 3 7 of IEC 61326 1 Equipment and systems intended for use in other electromagnetic environments for example in the process industry or in environments with potential...

Страница 17: ...DS CAN2 TECHNICAL REFERENCE MANUAL 11 Documentation version history DS CAN2 V20 2 17 17 Version Date Notes V20 2 12 10 2020 Small cosmetic updates V20 1 31 8 2020 New Template...

Отзывы: