DEWESOFT DS-CAM 175c Скачать руководство пользователя страница 37

DS-CAM-88c / DS-CAM-120c / DS-CAM-175c / DS-CAM-320c 

TECHNICAL REFERENCE MANUAL 

 

 
Restriction of Hazardous Substances 
This product has been classified as Monitoring and Control equipment and is outside the scope of the 
2002/95/EC RoHS Directive. However, we take care of our environment and the product is lead-free.

 

8.2.4. General safety and hazard warnings for all Dewesoft systems 

Safety of the operator and the unit depend on following these rules. 

Use this system under the terms of the specifications only to avoid any possible danger. 

Read your manual before operating the system. 

Observe local laws when using the instrument. 

DO NOT touch internal wiring! 

DO NOT use higher supply voltage than specified! 

Use only original plugs and cables for harnessing. 

You may not connect higher voltages than rated to any connectors. 

The power cable and connector serve as Power-Breaker. The cable must not exceed 3 meters, 
the disconnect function must be possible without tools. 

Maintenance must be executed by qualified staff only. 

During the use of the system, it might be possible to access other parts of a more comprehensive 
system. Please read and follow the safety instructions provided in the manuals of all other 
components regarding warning and security advice for using the system. 

With this product, only use the power cable delivered or defined for the host country. 

DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a 
voltage supply unit. 

Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth 
terminal), a non-interruptible safety earth ground must be provided from the mains power 
source to the product input wiring terminals. 

Please note the characteristics and indicators on the system to avoid fire or electric shocks. 
Before connecting the system, please read the corresponding specifications in the product 
manual carefully. 

The inputs must not, unless otherwise noted (CATx identification), be connected to the main 
circuit of category II, III and IV. 

The power cord separates the system from the power supply. Do not block the power cord, since 
it has to be accessible for the users. 

DO NOT use the system if equipment covers or shields are removed. 

If you assume the system is damaged, get it examined by authorized personnel only. 

Adverse environmental conditions are Moisture or high humidity Dust, flammable gases, fumes 
or dissolver Thunderstorm or thunderstorm conditions (except assembly PNA) Electrostatic 
fields, etc. 

The measurement category can be adjusted depending on module configuration. 

Any other use than described above may damage your system and is attended with dangers like 
short-circuiting, fire or electric shocks. 

The whole system must not be changed, rebuilt or opened. 

DO NOT operate damaged equipment: Whenever it is possible that the safety protection 
features built into this product have been impaired, either through physical damage, excessive 
moisture, or any other reason, REMOVE POWER and do not use the product until the safe 
operation can be verified by service-trained personnel. If necessary, return the product to 
Dewesoft sales and service office for service and repair to ensure that safety features are 
maintained. 

DS-CAM-88c / DS-CAM-120c / DS-CAM-175c / DS-CAM-320c DS-V20-2

37/40   

Содержание DS-CAM 175c

Страница 1: ...DS CAM 88c DS CAM 120c DS CAM 175c DS CAM 320c TECHNICAL REFERENCE MANUAL DS CAM 88c DS CAM 120c DS CAM 175c DS CAM 320c V20 1 1...

Страница 2: ...4 3 Benchmarks 19 5 Installation 20 5 1 DewesoftX full installer 20 5 2 Manual installation 22 5 2 1 Required files 22 5 2 1 Step by step instruction 23 6 Troubleshooting guide 30 7 Warranty informati...

Страница 3: ...DS CAM 88c DS CAM 120c DS CAM 175c DS CAM 320c TECHNICAL REFERENCE MANUAL 9 Documentation Version 40 DS CAM 88c DS CAM 120c DS CAM 175c DS CAM 320c DS V20 2 3 40...

Страница 4: ...ols and formats will be used throughout the document Important It gives you important information about the subject Please read carefully Hint It gives you a hint or provides additional information ab...

Страница 5: ...dustrial standard GigE Vision The standard introduced in 2006 provides a framework for transmitting high speed video and related control over Ethernet networks The benefits are high speed data transfe...

Страница 6: ...3 45 6 9 x 6 9 Dynamic range 35 dB auto gain function 32 dB auto gain function 71 6 dB auto gain function 74 4 dB auto gain function Shutter Full frame Full frame Electronic Global Shutter Electronic...

Страница 7: ...oHS GigE Vision GenICam PoE IEEE 802 3at CE FCC RoHS GigE Vision GenICam PoE IEEE 802 3at CE FCC RoHS GigE Vision GenICam PoE IEEE 802 3at CE FCC RoHS GigE Vision GenICam PoE IEEE 802 3at Power specif...

Страница 8: ...DS CAM 88c DS CAM 120c DS CAM 175c DS CAM 320c TECHNICAL REFERENCE MANUAL Illustration 2 Technical drawing of aluminum adapter plate DS CAM 88c DS CAM 120c DS CAM 175c DS CAM 320c DS V20 2 8 40...

Страница 9: ...DS CAM 175c Color camera DS CAM 320c Color camera 4 2 2 Accessories Type Usage LENS AZURE 1614mm Azure 1614mm C MOUNT lens CABLE UTP CAT 6 3m RJ45 CAT 6 cable for data ALU_PLATE_ADAPTER Aluminum plate...

Страница 10: ...and sync cable 12 pin Hirose connector splitted to 2 pin Lemo connector and 4 pin Lemo connector For SIRIUS usage H12f L1B7m L00B4m 3m Power and sync cable 12 pin Hirose connector splitted to 7 pin L...

Страница 11: ...3m and H12f L1B7m L00B4m 3m are the equal except the pinout is different from one another Refer to the tables below Illustration 16 Pinout of marked connector for H12f L1B2m L00B4m 3m cable Pin Name D...

Страница 12: ...5 6 12V Power 9 36 V DC 7 GND Ground 4 3 Connections On the rear side of the camera there are two connectors The 12pin HIROSE connector matching part Hirose HR10A10P 12S 73 contains the power trigger...

Страница 13: ...matching part Hirose HR10A 10P 12S 73 on camera rear side Pin Signal 1 GND for Power and RS232 2 Power 8 30 V DC 3 4 Camera In 1 TRIGGER 5 6 Camera Out 1 open emiter max 20 mA 7 Camera In GND 8 RxD RS...

Страница 14: ...to the camera contains the power from SBOX Power out and the trigger connected to the SYNC port of the SIRIUS slice The camera frames are now in perfect sync with the analog data acquired by Dewesoft...

Страница 15: ...re than one camera there is a special CAM BOX2 available which consists of wide range voltage input 9 36V an industrial Gigabit Ethernet Switch without Power over Ethernet No supply for DS CAM 600 Pow...

Страница 16: ...tration 8 CAM BOX2 pinout Mating cable connector FGG 1B 307CLAD52 Pin Pin assignment 1 2 3 4 CLK 5 6 12V 7 GND Power supply connector Illustration 8 Power supply Mating cable connector FGGJ 1B 302CLLD...

Страница 17: ...MANUAL Sync connector Illustration 8 Sync connector Mating cable connector FGG 00 304CLAD27Z Pin Pin assignment 1 2 3 CLK 4 GND 4 2 5 Connections Overview Illustration 9 DS CAM to SIRIUS connection ex...

Страница 18: ...to connect due to power limitation of DEWE 43A Illustration 11 DS CAM CAM BOX1 for power supply and synchronization Expanding up to four cameras Ethernet data cable is wired directly to the network c...

Страница 19: ...ected to the CAM BOX2 Setup 1 to 4 cameras connected over CAM BOX2 SBOX 128GB SSD max 190 MByte s write rate CPU Intel Core i7 QM57 2 0GHz 4GB RAM camera s clocked by SIRIUS Dewesoft X1 SP7 b358 GigEV...

Страница 20: ...e disk may be a limiting factor we used SSD We recommend to test cameras with your setup at about 0 8 max_FPS and higher to find where corrupted image frame lost or buffer overrun will occur 5 Install...

Страница 21: ...5c DS CAM 320c TECHNICAL REFERENCE MANUAL Illustration 6 Installation The last DewesoftX full installer can be downloaded here https download dewesoft com list dewesoftx DS CAM 88c DS CAM 120c DS CAM...

Страница 22: ...lation 5 2 1 Required files OptoStream SDK for GigE Vision Go to https download dewesoft com list plugins and download GigE package It includes the latest OptoStream SDK and Dewesoft driver for GigE V...

Страница 23: ...an administrator not just a user with admin rights Restart the PC after installation is complete After reboot be sure that OptoStream GEM Filter Driver is installed picture 1 under Local area Connecti...

Страница 24: ...working you can run OptoStreamViewer By right clicking on the camera model you can also set IP to fix if you prefer Illustration 9 OK cameras can be used close the OptoStreamViewer and start DewesoftX...

Страница 25: ...wesoftX 6th step Start DewesoftX and go to Options Settings Analog For triggered mode DewesoftX is clocking the camera check if your device such as DEWE 43 for example is set to Automatic or Clock Tri...

Страница 26: ...we have experienced good results with the Xvid codec uses multiple cores consider that AVI will stop recording after video file size reaches 2 GB compress after measurement if you have a triggered me...

Страница 27: ...he video channel Illustration 14 DewesoftX Channel setup add Video Hint Ensure the firmware version of Dewesoft hardware is up to date otherwise follow the instructions of how to do it in the Updating...

Страница 28: ...change the frame rate after typing the value the input field gets a yellow color confirm the value by pressing the Enter key Use the Advanced Settings if you want to change specific parameters of the...

Страница 29: ...DS CAM 88c DS CAM 120c DS CAM 175c DS CAM 320c TECHNICAL REFERENCE MANUAL Illustration 18 Advanced settings DS CAM 88c DS CAM 120c DS CAM 175c DS CAM 320c DS V20 2 29 40...

Страница 30: ...ttings if the DewesoftUSB device is set to Clock Trigger or Automatic Standalone Disable Trigger in hardware setup and check if it s working in free run mode This could potentially be a cable problem...

Страница 31: ...ess of the camera If you manually change the IP address please close DewesoftX start the OptoStreamViewer right click on the camera and select Set IP to device use the same subnet as the computer exam...

Страница 32: ...Cam_v2_4 bin Win32_i86 to Dewesoft s Addons folder Then restart DewesoftX Maximum frame rate VGA resolution only 36 fps When you adjust the framerate higher than 36 fps and it is always reset to 36 fp...

Страница 33: ...hernet packets larger than 1500 bytes This way less CPU time is spent for data reception therefore increasing performance and minimizing data loss Control panel network and internet view network statu...

Страница 34: ...eeds to be calibrated at regular intervals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed cali...

Страница 35: ...owners 7 7 Trademarks We take pride in our products and we take care that all key products and technologies are registered as trademarks all over the world The Dewesoft name is a registered trademark...

Страница 36: ...quirements All accessories shown in this document are available as an option and will not be shipped as standard parts 8 2 1 Environmental Considerations Information about the environmental impact of...

Страница 37: ...aving a protective earth terminal a non interruptible safety earth ground must be provided from the mains power source to the product input wiring terminals Please note the characteristics and indicat...

Страница 38: ...ng leads integrated circuits and so on are dry DO NOT use the system in rooms with flammable gases fumes or dust or in adverse environmental conditions Avoid operation in the immediate vicinity of hig...

Страница 39: ...ns in IEC 61000 6 2 or defined in 3 7 of IEC 61326 1 Equipment and systems intended for use in other electromagnetic environments for example in the process industry or in environments with potentiall...

Страница 40: ...om camera to DEWE 43 in section 2 2 4 1 0 5 27 11 12 Changed first FAQ to GigE checkbox in hardware setup missing 1 0 6 26 02 13 General update CAM box pinout more FAQs small corrections 1 0 7 02 07 1...

Отзывы: