Troubleshooting
3A8110C
31
To Test Functionality - Standard Series
1.
Using an Ohm meter, probe the ribbon
lines 2 and 3 and press the dispense
button. It should read ~0 ohms (Photo
A).
2.
If Ohm meter does not read ~0 ohms
when pressing the dispense button,
replace the switch.
To Test Functionality - Pro Series
1.
Using an Ohm meter, probe the ribbon
lines 2 and 3 and press the dispense
button. It should read ~0 ohms (Photo
B).
2.
Probe ribbon lines 1 and 4 and press the
Repeat button. It should read OL or
MOhms (Photo C).
3.
Probe ribbon lines 1 and 5 and press the
Repeat button. It should read OL or
MOhms (Photo D).
4.
Probe ribbon lines 4 and 5 and press the
Repeat button. It should read ~0 ohms
(Photo E).
5.
If Ohm meter does not read these
values, replace switch assembly.