background image

English

8

Diagnostic Safety Shutdown and Trouble Shooting

See the following troubleshooting guide for unit status and corrective action if necessary.

SYMPTOM 

 

       TROUBLE SHOOTING

 

 
High limit switch Open Circuit 

 

1) 

Make sure heater is cooled off, toggle switch to “OFF” position, wait 5 minutes and retry.

 

 

 

Sparks, calling for flame, but 

 

1) 

Check wiring to motor (per wiring schematic in manual).

no or slow motor operation 

 

2) 

Make sure that the pressure gauge plug is in place and not damaged.

 

 

 

3) 

Adjust pressure for proper heater operation per manual.

 

 

 

4) 

With heater disconnected from AC source, rotate fan clockwise to verify motor is free.

 

 

 

5) 

Remove air filter housing from motor and inspect the pump rotor for damage. If damaged, replace rotor assembly.

 

 

 

6) 

If wiring is correct, pump rotor is okay, and motor is not rotating freely, replace motor or power-pack assembly.

 

 

 

7) 

If problem persists, replace oil flame control assembly.

 

 

 

8) 

Check for spark arching from the electrode assembly, to the combustion cylinder.

 

 

 

9)  

Check the cad cell for 

continuity.

No Spark 

 

 

1)  

Check length and gage of extension cord for proper amp. draw. (Check requirements on page 5.)

 

 

 

2) 

Check wiring to igniter (per wiring schematic in manual).

 

 

 

3) 

Check gap between electrode probes (2.3 - 3 mm).

 

 

 

4) 

Still no spark, replace igniter assembly.

 

 

 

5) 

Replace oil flame control assembly.

Abnormal Motor Operation - 

 

1) 

Motor speed too low (Motor should operate at 3450rpm, except 50K at 1550rpms) - Replace motor. 

Motor overheats or Stops 

 

2) 

With heater disconnected from AC source, rotate fan clockwise to verify motor is free.

 

 

 

3) 

Remove air filter housing from motor and inspect the pump rotor for damage. If damaged, replace rotor assembly.

 

 

 

4) 

If wiring is correct, pump rotor is okay, and motor is not rotating freely, replace motor or power-pack assembly.

 

 

 

5) 

Replace oil flame control assembly.

Unable to Detect Flame 

 

1) 

Check wiring to cad cell (per wiring schematic in manual).

 

 

 

2) 

Clean cad cell photo cell.

 

 

 

a)  

Slide cad cell out of cad cell holder.

 

 

 

b)  

Push the photo cell out of the black rubber cad cell housing by pushing on the 2 purple wires.

 

 

 

c)  

Clean the photo cell with a soft cloth and rubbing alcohol.

 

 

 

d)  

Pull the photo cell back into the cad cell housing and reinstall into holder.

 

 

 

e)  

Test heater.

 

 

 

3) 

If the heater still does not operate, replace cad cell.

 

 

 

4) 

Replace oil flame control assembly.

Flame Control Failure 

 

1) 

Check wiring in heater (per wiring schematic in manual).

 

 

 

2) 

Replace oil flame control assembly.

Содержание DXH135KT

Страница 1: ...ructions Place instructions in a safe place for future reference Do not allow anyone who has not read these instructions to assemble adjust or operate the heater VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS Lisez et observez toutes les instructions Conservez ces instructions dans un endroit sécuritaire pour vous y référer ultérieurement Interdisez à quiconque n ayant pas lu les présentes directive...

Страница 2: ...ons Never use the heater in spaces which do or may contain volatile or airborne combustibles or products such as gasoline solvents paint thinner dust particles or unknown chemicals WARNING RISK OF FIRE OR EXPLOSION Do not use gasoline naphtha or volatile fuels Stop heater before adding fuels Always fill outdoors away from open flame Do not use external fuel source Do not operate heater where flammabl...

Страница 3: ...y of this or any other appliance WHAT TO DO IF YOU SMELL GAS Open windows DO NOT try to light any appliance DO NOT operate any electrical switches DO NOT use any telephone in building Immediately call the local gas supplier from an outside telephone Follow the gas supplier s instructions DO NOT touch any electrical switch do not use any phone in your building If you cannot reach your gas supplier ...

Страница 4: ... at 855 805 5745 Safety Precautions 1 Certified for use with No 1 K kerosene fuel Factory tested for use with No 2 K kerosene No 1 or No 2 Diesel No 1 or No 2 fuel oil or JP8 Jet A fuel and these fuels may be used as well Never use gasoline oil drained from crank cases naphtha paint thinners alcohol or any other highly flammable fuels Only store kerosene in containers marked Kerosene or Kerosine 2...

Страница 5: ...g with mounting hardware The wheels axle and mounting hardware are in a package Tools required are a 5 16 nut driver 3 8 open or adjustable wrench and standard pliers 1 Assemble the wheels onto the wheel support as shown 2 Install one of the cotter pins into the hole on one end of axle 3 Slide the large washer then wheel onto the axle next to the cotter pin 4 Slide the spacer onto the axle next to...

Страница 6: ...r for loose or damaged parts Check nuts and bolts to insure against looseness caused by vibration or rough handling Damaged parts should be repaired or replaced before using heater again Check heater operation to be sure it is operating normally See Servicing section for description of normal operation 2 FILTERS Dirty air or fuel filters will cause an imbalance in the air fuel mixture The best ind...

Страница 7: ...ections are tight before operating unit STORAGE Store the heater in a dry location free from fumes or dust At the end of each heating season clean the heater as described in the MAINTENANCE section Drain and flush the fuel tank with clean fuel The manufacturer recommends completely filling the tank with fuel for extended storage to minimize condensation inside the tank SERVICING A hazardous condit...

Страница 8: ...uirements on page 5 2 Check wiring to igniter per wiring schematic in manual 3 Check gap between electrode probes 2 3 3 mm 4 Still no spark replace igniter assembly 5 Replace oil flame control assembly Abnormal Motor Operation 1 Motor speed too low Motor should operate at 3450rpm except 50K at 1550rpms Replace motor Motor overheats or Stops 2 With heater disconnected from AC source rotate fan cloc...

Страница 9: ...22113 Front Leg 6 22168 22184 Axle 7 40981 40981 Wheel Assembly 8 28749 28749 Large Retainer Washer 9 28750 28750 Cotter Pin 10 28751 28751 Hub Cap 11 21897 21897 Wheel Spacer 12 21906 21907 Drape Guard 28787 28787 Hardware Kit DXH50K DXH75K 12 21905 21905 Drape Guard Not Shown Required in Canada PARTS LIST Handle Wheel Ass y Figure 1 Handle and wheel assembly for DXH135K and DXH185K only Handle W...

Страница 10: ...s Rotor Rotor Vanes and Rotor Drive 30 F221887 F221887 F221887 F221887 Filter Kit Includes Inlet Filter Outlet Filter Gasket Fuel Filter Screen 34 F266842 F266842 F266842 F266842 Pump Adjustment Kit Includes Plug Adj Screw Spring and Ball Bearing 39 40819 40819 40820 40820 Inlet Grill Assembly 40 40821 40821 40822 40824 Bottom Half Shell 41 26227 26227 Snap Bushing 42 43 40825 40953 40826 40826 Co...

Страница 11: ...English 11 43 44 49 45 1 2 3 4 16 15 8 7 17 9 12 11 13 14 18 40 59 60 57 58 55 68 70 65 56 66 50 46 48 61 47 67 19 24 6 30 29 34 39 20 23 5 41 ...

Страница 12: ...TION REGARDING SERVICE Please call Toll Free 855 805 5745 www dewalt com Our office hours are 8 00 AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY DeWalt warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase DeWalt wi...

Отзывы: