15
English
5. Move the Auto/Off switch to “AUTO (-)” position. The
compressor will start.
6. Run the compressor for 30 minutes. Make sure the drain valve
and all air lines are open so there is only a minimal air pressure
build-up in tank.
NOTE:
After about 30 minutes, If the unit does
not operate properly, SHUT DOWN IMMEDIATELY, and contact
Product Service.
7. Check all air line fittings and connections/piping for air leaks
by applying a soap solution. Correct if necessary.
NOTE:
Minor
leaks can cause the air compressor to overwork, resulting in
premature breakdown or inadequate performance.
8. Check for excessive vibration.
9. After 30 minutes, turn the Auto/Off switch to the “OFF (O)”
position.
10. Close the drain valve.
11. Turn the Auto/Off switch to the “AUTO (-)” position. The air
receiver will fill to “cut-out” pressure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up (Fig. 2)
1. Every day check the sight glass to ensure that the level of oil in
the pump is at the required level.
2. Place Auto/Off switch to “OFF (O)”.
3. Close the drain valve
.
4. Visually inspect air lines and fittings for leaks.
5. Check safety valve. See
To Check Safety Valve
under
Maintenance
.
6. Turn the regulator knob counterclockwise to set the outlet
pressure to zero.
7. Attach hose and accessories.
WARNING:
Risk of unsafe operation. Firmly grasp air hose in
hand when installing or disconnecting to prevent hose whip.
WARNING:
Risk of unsafe operation. Do not use damaged or
worn accessories.
NOTE:
The hose or accessory will require a quick connect plug if
the air outlet is equipped with a quick connect socket.
WARNING:
Risk of bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
CAUTION:
Risk of unsafe operation. Compressed air from the
unit may contain wa ter condensation and oil mist. Do not spray un fil-
tered air at an item that could be damaged by moisture. Some air
tools and accessories may require filtered air. Read the in struc tions
for the air tools and accessories.
How to Start
1. Turn the Auto/Off switch to “AUTO (-)” and allow tank pressure
to build. Motor will stop when tank pressure reaches “cut-out”
pressure.
2. Turn the regulator knob clockwise to increase pressure.
IMPORTANT:
When using regulator and other accessories refer to
the manufacturers instructions.
WARNING:
Risk of bursting. If any unusual noise or vibration is
noticed, stop the compressor immediately and have it checked by a
trained service technician.