  1.   Check to make sure that the inverter is turned off and no flammable 

fumes are present in the installation area.

  2.  Turn the red plastic cap (counterclockwise) on the inverter’s positive 

(+) cable post and remove. Attach the positive connector at the 

end of the red battery clip cable into the groove of the positive (+) 

cable post. Replace the cap and turn clockwise to secure. Do not 

over-tighten.

  3. Connect the red battery clip to the POSITIVE terminal of the battery.
 4. Turn the black plastic cap (counterclockwise) on the inverter’s 

negative (–) cable post and remove. Attach the negative connector 

at the end of the black battery clip cable into the groove of the 

negative (–) cable post. Replace the cap and turn clockwise to 

secure. Do not over-tighten.

 5. Connect the black battery clip to the NEGATIVE terminal of the 

battery.

  6. Make sure that all connections between cables and terminals are 

secure.

  7. Press the power button to turn the inverter on. A beep will sound, 

the backlit LCD and the USB power/fault indicators will activate 

to indicate the inverter is operating properly and the 120 volt AC 

outlets are ready to power appliances that draw up to 1000W 

continuous and USB outlets up to 3.1A.

Note: 

Refer to “Power and Fault Indicators on the LCD Display” for 

an explanation of the operating and fault icons. If a fault icon appears, 

refer to the “Protective Features” section and the “Troubleshooting” 

section of this manual.

DIRECT HARDWIRING TO POWER SOURCE (OPTIONAL 

CONNECTION METHOD; HARDWARE NOT INCLUDED)

Use #8 AWG wire if the inverter to power source connection is 4 feet 

or less. For cable lengths up to 10ft use #6 AWG wire.* In either case, 

protect the positive (+) wire from shorts by installing a 150 amp fuse 

or circuit breaker close to the DC power source (battery) terminal. 

The cable, fuse holder and fuse (not supplied) can be purchased at 

an electrical supply company. Manufacturer provides the installation 

cable set (refer to the “Installation” section of this manual).

*For cable lengths exceeding 10 feet from inverter to battery, contact 

manufacturer for additional information. 

  1.   Check to make sure that the inverter is turned off and no flammable 

fumes are present in the installation area.

  2.  Identify the positive (+) and negative (–) DC power source (battery) 

terminals.

  3. Install a fuse holder or breaker close to the positive (+) terminal of 

the DC source (battery).

  4. Connect a length of wire on one side of the fuse holder or circuit 

breaker. Connect the other end of the wire to the positive (+, red) 

O-ring of the supplied cable set, securing them using the supplied 

bolt, washer and the wing nuts.

  5.  Connect a length of wire on one side of the negative (–) DC power 

source (battery) terminal. Connect the other end of the wire to the 

negative (–, black) O-ring of the supplied cable set, securing them 

using the supplied bolt, washer and the wing nuts.

 6. Connect a short length of wire to the other terminal of the fuse 

holder or circuit breaker. Mark it “positive” or “+”.

  7. Connect the free end of the fuse or breaker wire to the positive (+) 

terminal of the DC power source (battery).

  8. Insert a fuse appropriate to the inverter in the fuse holder.
  9.  Check to make sure the power button is turned off.
10. Turn the red plastic cap on the inverter’s positive (+) cable post 

(counterclockwise) and remove. Attach the positive slide-in 

connector at the end of the supplied red cable set into the groove 

of the positive (+) cable post. Replace the cap and turn clockwise 

to secure. Do not over-tighten.

11. Turn the black plastic cap on the inverter’s negative (–) cable 

post (counterclockwise) and remove. Attach the negative slide-in 

Installation

Your inverter will provide you with continuous electrical power when 

powered by a reliable 12 volt DC source, such as a vehicle battery or 

a multiple battery configuration. This manual does not describe all of 

the possible configurations.

Mounting the Inverter

Tools Required:

 four BA4x14 screws in a set and Philips head 

screwdriver (NOT supplied).
The inverter comes equipped with mounting brackets for long-term 

installation. The manufacturer recommends using BA4x14 screws 

in a set with a standard Philips head screwdriver (none of these are 

supplied). User may choose to use different screws appropriate to the 

mounting surface. 
Secure the inverter to a flat surface, observing all cautions regarding 

installation found in this manual.

CAUTION

 – To avoid the risk of property damage:  Only mount the 

inverter on a level, stable surface, assuring that all screws are tightened 

securely and observing all of the cautions and recommendations 

regarding installation found in this manual.

Operating Environment

For best operating results, your inverter should be placed on a flat 

surface, such as the ground, car floor or seat, or other solid surface 

to help diffuse the heat that is generated. Position the inverter as close 

to the DC power source as possible.
The inverter should only be operated in locations that meet the following 

criteria:
DRY – Do not allow water and/or other liquids to come into contact 

with the inverter.
COOL – Surrounding air temperature should ideally be 50-68°F (10-

20°C). Do not place the inverter on or near a heating vent or any piece 

of equipment that is generating heat above room temperature. Keep 

the inverter out of direct sunlight.
VENTILATED – Allow at least three inches of clearance from other 

objects to ensure free air circulation around the inverter. Never place 

items on or over the inverter during operation.
SAFE – Do not locate inverters in an area, room or compartment 

where explosives or flammable fumes might be present, such as 

engine rooms, engine compartments, and boats or small, unvented 

battery compartments.

Connecting the Inverter

The inverter must be connected only to batteries with a nominal output 

voltage of 12 volts. The unit will not operate from a 6 volt battery and 

will sustain permanent damage if connected to a 24 volt battery. 
The standard North American 120 volt AC outlets and USB charging 

ports allow simultaneous operation of multiple devices. Simply plug the 

equipment into the unit and operate normally. Ensure that the wattage 

of all equipment simultaneously plugged into the unit does not exceed 

1000 watts continuous.

CAUTION

 – To avoid the risk of property damage: Always connect 

the unit to the 12 volt DC power source before plugging any devices 

into the unit.

Connection to Power Source

The Power Inverter comes equipped Battery Clips for connection to 

a power source.

CONNECTING TO A POWER SOURCE USING THE PROVIDED 

BATTERY CLIPS WITH SLIDE-IN CONNECTORS

Use the provided Battery Clips (with cables and slide-in connectors) 

to connect the Power Inverter directly to the 12 volt power source as 

follows:

DXAEPI1000_ManualENSP_080320.indd   10-11

DXAEPI1000_ManualENSP_080320.indd   10-11

8/3/2020   1:40:37 PM

8/3/2020   1:40:37 PM

Содержание DXAEPI1000

Страница 1: ...os INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES If you have questions or comments contact us Si tiene dudas o comentarios contáctenos 1 888 394 3392 RD080320 DXAEPI1000_ManualENSP_080320 indd 32 1 DXAEPI1000_ManualENSP_080320 indd 32 1 8 3 2020 1 40 35 PM 8 3 2020 1 40 35 PM ...

Страница 2: ...or damaged parts Any part that is damaged should be properly repaired or replaced by manufacturer unless otherwise indicated elsewhere in this instruction manual before further use Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain ...

Страница 3: ...ding electronic device to confirm that it can be used with this type of USB Port Specific Safety Instructions for Inverters WARNING To reduce the risk of electric shock Do not connect to AC distribution wiring Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This includes DC cigarette lighter type plug connection This unit is NOT approved for ignit...

Страница 4: ...ts 120 to determine the wattage Resistive loads are the easiest for the inverter to run however it will not run larger resistive loads such as electric stoves and heaters which require far more wattage than the inverter can deliver Inductive loads such as TVs and stereos require more current to operate than do resistive loads of the same wattage rating WARNING If the product does not operate norma...

Страница 5: ...put voltage exceeds 15 volts Your inverter is engineered to have standard electrical and electronic equipment directly connected to it in the manner described in the Installation section of this Instruction Manual Do not connect the inverter to household or RV AC distribution wiring Do not connect the inverter to any AC load circuit in which the neutral conductor is connected to ground earth or to...

Страница 6: ...tive slide in connector at the end of the supplied red cable set into the groove of the positive cable post Replace the cap and turn clockwise to secure Do not over tighten 11 Turn the black plastic cap on the inverter s negative cable post counterclockwise and remove Attach the negative slide in Installation Your inverter will provide you with continuous electrical power when powered by a reliabl...

Страница 7: ...f a fault icon appears refer to the Protective Features section and the Troubleshooting section of this manual 14 Test the inverter by turning it on and plugging in a 100 watt lamp or equipment If the inverter is not operating properly then rrefer to the Protective Features section and the Troubleshooting section of this manual CAUTIONS The cable and fuse sizes given here are a general recommendat...

Страница 8: ... instructions for care and maintenance for the product This warranty gives you the original retail purchaser specific legal rights and you may have other rights which vary in certain states or provinces This product is not intended for commercial use 90 DAY REFUND POLICY If you are not completely satisfied with the performance of this product for any reason you can return it within ninety 90 days ...

Страница 9: ...ios es un DeWalt inversor de potencia de 1000W configurado para suministrar potencia continua en forma de dos tomacorrientes de 120 voltios CA y tres puertos de alimentación USB de 5 voltios para ejecutar la mayoría de los hogares o aparatos electrónicos Instrucciones importantes sobre seguridad 1 Conserve estas instrucciones 2 Preste atención a todas las advertencias 3 Obedezca todas las adverten...

Страница 10: ...correctamente es posible que lo indique el manual de instrucciones de su producto En caso de duda debe comunicarse con el fabricante de su producto ANTES DE UTILIZARLO 11 El aparato no quedará expuesto a goteos ni a salpicaduras y no se colocarán sobre el aparato objetos llenos de líquido tales como jarrones LEA TODAS LAS INSTRUCCIONES Instrucciones de seguridad específicas para los inversores ADV...

Страница 11: ...e uso doméstico o un inversor de onda senoidal pura para poder funcionar correctamente Este inversor puede dañar su producto si éste contiene Fuentes de alimentación controladas por microprocesador Cargadores de baterías sin transformador Fuentes de energía con acoplamiento capacitivo Si se utiliza un producto incompatible con este inversor Es posible que el producto no funcione en absoluto sin in...

Страница 12: ...oltaje de entrada excede los 15 voltios Su inversor está diseñado para tener equipos eléctricos y electrónicos estándar conectados directamente a él de la manera descrita en la sección Instalación de este manual de instrucciones No conecte el Inversor eléctrico a cableados de distribución de CA de vehículos recreativos o para uso doméstico No conecte el inversor a cualquier circuito de carga de CA...

Страница 13: ...entes en el área de instalación 2 Identifique los terminales positivo y negativo batería de la fuente de energía de cd Esto indica una condición de la sobrecarga o de avería del cortocircuito El icono de la toma de CA parpadea y la lectura digital muestra 0W El icono de fallo y el icono USB se iluminará sólida y las barras en el icono de la batería representar el nivel de voltaje de la fuente de a...

Страница 14: ... un lado de la negativa fuente de alimentación de CC batería terminal Conecte el otro extremo del cable al terminal negativo negro Junta tórica del conjunto del cable suministrado asegurándolos con el tornillo suministrado la arandela y las tuercas de mariposa 6 Conecte una prolongación corta del cable al otro terminal del soporte del fusible o al interruptor automático Márquelo como positivo o 7 ...

Страница 15: ...mas Problemas específicos de salida de CA Cuando se utilizan las tomas de CA de 120V la unidad supervisará las siguientes condiciones de falla fallo térmico fallo de voltaje de batería bajo y alto sobrecarga y cortocircuito consulte la sección Características de protección Problema Solución posible Si existe una condición de fallo en cualquiera de los tomacorrientes CA la pantalla LCD mostrará la ...

Страница 16: ... puede ser requerida por el fabricante 2 Devuelva el producto a la tienda donde el producto fue comprado para un intercambio siempre y cuando se trate de un minorista participante Devoluciones al minorista deben hacerse dentro del plazo de póliza de devoluciones del minorista para intercambios solamente por lo general 30 a 90 días después de la fecha de compra La prueba de compra puede ser requeri...