1 Instruction manual
1 Exploded drawing
• Check for damage to the tool, parts or
accessories which may have occurred during
transport.
• Take the time to thoroughly read and understand
this manual prior to operation.
Description (fig. A)
Your D
E
WALT DW62 Circular Saw is a versatile
Power Tool that has been designed for professional
sawing applications.
1 ON/OFF-switch
2 Lock-off button
3 Locking screw for depth of cut
4 Motor cover
5 Carrying handle
6 Depth of cut adjustment/front handle
7 Parallel fence
8 Blade guard
9 Blade bolt
10 Riving knife
11 Saw shoe
12 Dust extraction outlet
13 Depth of cut scale
14 Bevel scale
15 Locking screw for bevel locking system
16 Locking screw for parallel fence
17 Mark for bevel cut
18 Mark for straight cut
19 Parallel fence scale
Electrical safety
The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
E
WALT tool is double insulated in
accordance with EN 50144; therefore no
earth wire is required.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
E
WALT repair agent or a qualified electrician.
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
.
For 115 V tools, use plugs to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
triple-core extension cable suitable for the power
input of this tool (see technical data). The minimum
conductor size is 1.5 mm
2
. When using a cable reel,
always unwind the cable completely.
Also refer to the table below.
Conductor size (mm
2
)
Cable rating (Amperes)
0.75
6
1.00
10
1.50
15
2.50
20
4.00
25
Cable length (m)
7.5
15
25
30
45
60
Содержание DW62
Страница 1: ...81 DW62 ...
Страница 3: ...83 ...
Страница 5: ...85 A 6 1 2 5 3 4 16 13 15 16 14 17 18 19 R 12 11 10 9 8 7 ...
Страница 6: ...86 C B 21 22 19 7 16 11 20 11 15 14 ...
Страница 7: ...87 D E R 8 23 9 R 10 3 mm MAX 2 5 mm ...
Страница 8: ...88 ...
Страница 86: ...78 ...
Страница 87: ...79 ...
Страница 88: ...80 ...