40
E N G L I S H
1 Pair of glasses
1 Kitbox
1 Charger (DW077K/DW077KH)
1 Battery pack (DW077K/DW077KH)
1 Instruction manual
• Take the time to thoroughly read and understand
this manual prior to operation.
Description (fig. A)
The rotary laser DW077 has been designed to project
laser lines to aid in professional applications.
The tool can be used both inside and outside for
horizontal (level) and vertical (plumb) alignment.
The tool can also produce a stationary laser dot that
can be directed manually to establish or transfer a
mark. The applications range from drop-ceiling
installation and wall layout to foundation leveling and
deck building.
The tool accepts D
E
WALT battery packs of 9.6, 12,
14.4 and 18 V.
1 On/off switch
2 Carrying handle
3 Leveling knob
4 Wall mount
5 Rack pinion locking knob
6 Wall mount clamp
7 Wall mount clamp lock
8 Fitting knob
9 Rack pinion wheel
10 Rotary laser head
11 Battery pack
Charger
Your DE9116 charger accepts D
E
WALT NiCd and
NiMH battery packs ranging from 7.2 V to 18 V.
11 Battery pack
12 Release buttons
13 Charger
14 Charging indicator (red)
Display
15 Power indicator
16 Leveling indicator (X-axis)
17 Leveling indicator (Y-axis)
18 Scan mode activation key
19 Rotation speed setting key
20 Adjustment keys left/right
Remote control
18 Scan mode activation key
19 Rotation speed setting key
20 Adjustment keys left/right
21 Adjustment keys up/down
22 Manual adjustment key
Electrical safety
The electric motor has been designed for various
voltages (see technical data). Always check that the
battery pack power corresponds to the voltage on
the rating plate. Also make sure that the voltage of
your charger corresponds to that of your mains.
Your D
E
WALT charger is double
insulated in accordance with EN 60335.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
E
WALT repair agent or a qualified electrician.
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (11).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Содержание DW077
Страница 1: ...1 DW077 ...
Страница 3: ...3 A 9 10 11 20 19 18 6 2 1 7 8 14 13 11 12 21 5 4 3 22 18 19 20 1 16 15 17 ...
Страница 4: ...4 11 15 12 B C1 ...
Страница 5: ...5 24 11 24 11 C3 C2 C4 D1 25 ...
Страница 6: ...6 6 7 4 8 27 26 3 4 6 3 4 7 D2 D3 D4 ...
Страница 7: ...7 29 28 30 D5 E1 E2 F1 ...
Страница 8: ...8 9 F2 F4 F5 F3 ...
Страница 9: ...9 19 18 20 19 18 21 20 10 20 20 21 19 19 G H1 H2 I ...
Страница 10: ...10 31 31 31 32 31 J1 J2 ...
Страница 11: ...11 K1 K2 K3 K4 ...
Страница 12: ...12 L1 L2 ...
Страница 167: ...167 ...