Dewalt DW03050
10
EN
Message Codes
If the message
Error
does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message
InFo
appears with a
number, press the Clear button and
observe the following instructions:
Care
•
Clean the device with a damp, soft cloth.
•
Never immerse the device in water.
•
Never use aggressive cleaning agents
or solvents.
Warranty
Europe:
•
30 day no risk satisfaction guarantee
•
One year free service
•
One year full warranty
Detailed information are available on the
internet at www.2helpU.com.
North America:
•
Three year limited warranty
•
One year free service
•
90 day money back guarantee
Detailed information are available on the
internet at www.dewalt.com.
Safety Instructions
The person responsible for the instrument
must ensure that all users understand
these directions and adhere to them.
Areas of responsibility
Responsibilities of the manufacturer
of the original equipment:
Europe:
DEWALT
D-65510 Idstein, Germany
www.2helpU.com
www.dewalt.eu
North America:
DEWALT Industrial Tool Co.
Baltimore, MD21286, USA
For service call 1-800-4-DEWALT.
www.dewalt.com
The company above is responsible for
supplying the product, including the User
Manual in a completely safe condition.
The company above is not responsible for
third party accessories.
Responsibilities of the person in
charge of the instrument:
•
To understand the safety instructions on
the product and the instructions in the
User Manual.
•
To be familiar with local safety regula-
tions relating to accident prevention.
•
Always prevent access to the product by
unauthorised personnel.
No.
Cause
Correction
204
Calculation error
Perform measurement
again.
252
Temperature too
high
Let device cool down.
253
Temperature too
low
Warm device up.
255
Received signal too
weak, measuring
time too long
Change target surface
(e.g. white paper).
256
Received signal too
high
Change target surface
(e.g. white paper).
257
Too much back-
ground light
Shadow target area.
258
Measurement
outside of meas-
uring range
Correct range.
260
Laser beam inter-
rupted
Repeat measurement.