10
E
The Stud Sensor is not Finding Studs
• Make sure the batteries are working.
• Make sure you have placed the stud sensor on a wall made of drywall or
another common building material. The stud sensor will not work on walls
made of concrete, mortar, block, brick work, plaster, carpeting, foil- faced
materials, metallic surfaces, or ceramic tile.
• Make sure you have placed the stud sensor flat against the wall, the stud
sensor is in a vertical position (parallel to a door or window), and you are
pressing and holding
(Figure
A
3
) as you move the stud sensor
SLOWLY
against the wall.
• Make sure the wall is not too thick. The DW0300 stud sensor can be used
to detect wood studs on walls < 1” (25mm) thick or metal studs on walls <
1.5” (38mm) thick.
• Make sure the wall has a smooth surface.
• Make sure the temperature is within the specified
Operating Range
and
Relative Humidity
.
The Stud Sensor is not Finding Metal Objects
• Make sure the batteries are working.
• Make sure you have placed the stud sensor on a wall made of drywall or
another common building material. The stud sensor will not work on walls
made of concrete, mortar, block, brick work, plaster, carpeting, foil- faced
materials, metallic surfaces, or ceramic tile.
• Make sure you have placed the stud sensor flat against the wall, the stud
sensor is in a vertical position (parallel to a door or window), and you are
pressing and holding
(Figure
A
2
) as you move the stud sensor
SLOWLY
against the wall.
• Make sure the wall is not too thick. The DW0300 stud sensor can be used
to detect Non-Ferrous Metal (e.g., copper) on walls < 2” (51mm) thick or
Ferrous Metal (contains iron) on walls < 3” (76.2mm) thick.
• Make sure the wall has a smooth surface.
• Make sure the temperature is within the specified
Operating Range
and
Relative Humidity
.
Service and Repairs
Note:
Disassembling the tool will void all warranties on the product.
To assure product SAFETY and RELIABILITY, repairs, maintenance and
adjustment should be performed by authorized service centers. Service
or maintenance performed by unqualified personnel may result in a risk of
injury. To locate your nearest D
E
WALT
service center, go to
www.D
E
WALT
.
com
.
Warranty
Go to www.
D
E
WALT
.com
for the latest warranty information.
DEWALT MPP2 STUD SENSOR - DW0300 - User Manual - NA - MAY 2019.indd 10
5/21/2019 3:37:33 PM
Содержание DW0300
Страница 3: ...C B 1 2 3 DEWALT MPP2 STUD SENSOR DW0300 User Manual NA MAY 2019 indd 3 5 21 2019 3 37 22 PM ...
Страница 4: ...D Figures 4 DEWALT MPP2 STUD SENSOR DW0300 User Manual NA MAY 2019 indd 4 5 21 2019 3 37 25 PM ...
Страница 6: ...F 6 E DEWALT MPP2 STUD SENSOR DW0300 User Manual NA MAY 2019 indd 6 5 21 2019 3 37 29 PM ...
Страница 27: ...Notes DEWALT MPP2 STUD SENSOR DW0300 User Manual NA MAY 2019 indd 27 5 21 2019 3 37 41 PM ...