15
English
d. If charging problems persist, take the tool, battery pack and
charger to your local service center.
4. The battery pack should be recharged when it fails to produce
sufficient power on jobs which were easily done previously.
DO NOT CONTINUE to use under these conditions. Follow
the charging procedure. You may also charge a partially used
pack whenever you desire with no adverse affect on the battery
pack.
5. Under certain conditions, with the charger plugged into the
power supply, the exposed charging contacts inside the charger
can be shorted by foreign material. Foreign materials of a
conductive nature such as, but not limited to, steel wool,
aluminum foil, or any buildup of metallic particles should be kept
away from charger cavities. Always unplug the charger from the
power supply when there is no battery pack in the cavity. Unplug
charger before attempting to clean.
6. Do not freeze or immerse charger in water or any other liquid.
WARNING:
Shock hazard. Don’t allow any liquid to get inside
charger. Electric shock may result.
cAutIoN:
Never attempt to open the battery pack for any reason.
If the plastic housing of the battery pack breaks or cracks, return to
a service center for recycling.
Storage recommendations
1. The best storage place is one that is cool and dry away from
direct sunlight and excess heat or cold.
2. Long storage will not harm the battery pack or charger. Under
proper conditions, they can be stored for 5 years or more.
SAvE ThESE InSTrucTIonS For
FuTurE uSE
InSTALLATIon
Pressure Washer Assembly (Fig. 1)
1. Place handle assembly (A) onto frame, depress
B
A
the snap buttons, and slide the handle assembly
onto the frame (B) until snap buttons are secured
in place.
cAutIoN:
Risk of personal injury. avoid placing
hands between handle and frame when assembling
to prevent pinching.
2. Attach high-pressure hose (C) to quick connect spray gun
3. Connect quick connect spray wand (E) to spray gun.
4. Thread the side handle (R) into spray gun and tighten to desired
position.
R
E
C
5. Place the nozzle holder (G) onto the panel assembly (F) and
push each nozzle holder into place.