Open Window Detection

 

 

 

When the heater is in operation it is automatically in open window detection mode and 
will shut down if the ambient temperature rapidly falls below 3 degrees or more.

 

 

Delete Open Window Detection

 

 

 

Open window detection is an integrated function of the heater and cannot be switched 
off, thus, the function is deactivated by ceasing power by pressing the power button (20). 

 

 

Signal Sound

 

 

An  acoustic  signal  sounds  each  time  a  key  is  pressed  on  the  unit.  If  a  button  is  held 
continuously the unit will only signal once.

 

 

Child Lock

 

 

When the unit is in operation, press the up (10) and down (11) buttons simultaneously for 
3 seconds. The control panel will now be locked. The temperature display (15) first shows 
‘’[]“ and switches to solely displaying the room temperature after 5 seconds. 

 

 

Unlock Child Lock

 

 

Method 1: Press the up (10) and down (11) buttons for 3 seconds and the child lock is 
deactivated.

 

 

Method  2:  Switch  off  the  device  using  the  power  button (20).  The  unit  will then enter 
standby mode.

 

 

Method 3: Turn off the power supply by pressing the power switch (21).

 

 

CLEANING & MAINTENANCE

 

Cleaning

 

Do not use abrasive cleaning products on this appliance. Clean with a damp cloth (not wet)

 

rinsed in hot soapy water only. Always remove plug from the mains supply before cleaning.

 

 

The heater requires regular cleaning to ensure trouble-free operation:

 

 

 

Unplug the heater from the mains supply before cleaning.

 

 

Ensure that the heater has been allowed to cool down completely before cleaning.

 

 

Use a damp cloth (not wet) to wipe the exterior of the heater to remove dust and dirt.

 

 

Use a vacuum cleaner to remove dust and fluff from around the grilles.

 

 

Ensure the heater is dry before plugging back into the mains supply.

 

Service

 

When you require service, contact your local dealer.

 

Replacement of supply cord

 

If the supply cord is damaged must be replaced by a service agent or

 

equivalent qualified person to prevent a hazard.

 

 

Содержание DVM1000W

Страница 1: ...ELECTRIC CONVECTOR HEATER SLIMLINE PANEL HEATER WITH DIGITAL TIMER MODEL s DVM1000W DVM1500W DVM2000W DVM2400W User Instructions Please read and save these instructions...

Страница 2: ...ot let bare skin touch hot surface Switch off and leave to cool before moving Do not use the appliance to dry clothes Do not insert or allow foreign object or metal utensils to enter any ventilation o...

Страница 3: ...ce The appliance must not be located immediately below a socket outlet Do not use this appliance with another programmer timer or any other device that switches the heater on automatically since a fir...

Страница 4: ...4 APPLIANCE OVERVIEW Fig 1 Circuit Diagram Air Outlet Control Panel Power Switch Castor Wheel Stand Tip over switch Heating element KSD thermostat KSD thermostat Temperature sensor Switch...

Страница 5: ...lt is MON Monday The hour display 17 the minute display 16 of the time and the temperature display 15 in degrees Celsius 35 is the default You will need to set the correct time and this will then be s...

Страница 6: ...of the timer to cease heating Press the up 10 and down 11 buttons to select the hour if the selected hour is prior to the current hour the system automatically rolls over to the following day 3 Press...

Страница 7: ...acity 4 shows LO is deactivated In the case of partial capacity heating LO is activated on the display 4 and HI is deactivated on the display 5 Manual Mode and Auto Mode Press the M A mode selection b...

Страница 8: ...for 3 seconds and the child lock is deactivated Method 2 Switch off the device using the power button 20 The unit will then enter standby mode Method 3 Turn off the power supply by pressing the power...

Страница 9: ...heater in the sturdy position 2 The heater should be installed so that the controls cannot be touched by a person using a bath or shower 3 The heater should be installed so that it is not located dire...

Страница 10: ...M2000W DVM2400W Rated Power 500W 1000W 750W 1500W 1000W 2000W 1200W 2400W Rated Voltage 220 240V 50Hz Dimensions mm W460 x D107 x H400 W690 x D107 x H400 W830 x D107 x H400 W950 x D107 x 400 Room Cove...

Страница 11: ...no Electronic heat charge control with room and or outdoor temperature feedback no Fan assisted heat output no Type of heat output room temperature control Single stage heat output and no room tempera...

Страница 12: ...uctions are excluded Consequential costs such as labour charges or damage to surroundings are expressly excluded Contact Us If you experience a problem with this product you should first contact us on...

Отзывы: