7

 

the stop time, the system cancels this heating phase.

 

6.

 

Press the "Set" button (13) to confirm the first period. 

 

7.

 

Repeat the above procedure to set the timer for the remaining three segments. If you do 
not wish to set any further heating segments press the “Set” button repeatedly until you 
reach the end of heating segment four and the heater will store solely the first heating 
segment.

 

 

Power Off

 

 

Press the power button (20) to turn the heater on or off. If you shut down the system while 
it is in automatic mode, it will work according to the scheduled procedure. 

 

 

However, if the unit is to be switched off for a long time, you must switch the system to 
manual  mode  and  then  off.  If  the  system  is  outside  the  preset  timer,  it  switches  off  1 
second after pressing the power button (20).

 

 

Half Power and Full Power Selection

 

 

Press the heating power button (2) to change the power to partial or full load.

 

 

At full heating capacity, “HI” is shown in the display (5) and half heating capacity (4) shows 
"LO" is deactivated.

 

 

In  the  case  of  partial  capacity  heating,  "LO"  is  activated  on  the  display  (4)  and  "HI"  is 
deactivated on the display (5).

 

 

Manual Mode and Auto Mode

 

 

Press the “M/A” mode selection button (19) to change the mode to Manual or Auto.

 

 

In manual mode, the display (7) shows an "M" while the "A" is hidden on the display.

 

 

In auto mode, the display (8) shows an "A" and the "M" is hidden on the display.

 

 

Shutdown Memory Function

 

 

Press the power switch (20) to turn the unit off and on again. When the unit is switched 
back on the temperature default is the last set and the previously scheduled timers are 
still activated.

 

 

Both  the  Auto  Mode  Timer  and  the  Manual  Mode  Timer  have  a  shutdown  memory 
function

 

 

Switching off the Electrical Memory Function

 

 

If the unit is unexpectedly turned off or there is a sudden power failure, only the power 
indicator (1) lights up when the power is back on and the system is in standby.

 

 

Press the power button (20) to turn the system back on. The system operates in the last 
mode in use before the power outage.

 

 

Delete Timers

 

 

Hold the "OK" button (12) for 5 seconds until a "di" tone is sounded, all prior daily and 
weekly timers will now be erased.

 

 
 

Содержание DVM1000W

Страница 1: ...ELECTRIC CONVECTOR HEATER SLIMLINE PANEL HEATER WITH DIGITAL TIMER MODEL s DVM1000W DVM1500W DVM2000W DVM2400W User Instructions Please read and save these instructions...

Страница 2: ...ot let bare skin touch hot surface Switch off and leave to cool before moving Do not use the appliance to dry clothes Do not insert or allow foreign object or metal utensils to enter any ventilation o...

Страница 3: ...ce The appliance must not be located immediately below a socket outlet Do not use this appliance with another programmer timer or any other device that switches the heater on automatically since a fir...

Страница 4: ...4 APPLIANCE OVERVIEW Fig 1 Circuit Diagram Air Outlet Control Panel Power Switch Castor Wheel Stand Tip over switch Heating element KSD thermostat KSD thermostat Temperature sensor Switch...

Страница 5: ...lt is MON Monday The hour display 17 the minute display 16 of the time and the temperature display 15 in degrees Celsius 35 is the default You will need to set the correct time and this will then be s...

Страница 6: ...of the timer to cease heating Press the up 10 and down 11 buttons to select the hour if the selected hour is prior to the current hour the system automatically rolls over to the following day 3 Press...

Страница 7: ...acity 4 shows LO is deactivated In the case of partial capacity heating LO is activated on the display 4 and HI is deactivated on the display 5 Manual Mode and Auto Mode Press the M A mode selection b...

Страница 8: ...for 3 seconds and the child lock is deactivated Method 2 Switch off the device using the power button 20 The unit will then enter standby mode Method 3 Turn off the power supply by pressing the power...

Страница 9: ...heater in the sturdy position 2 The heater should be installed so that the controls cannot be touched by a person using a bath or shower 3 The heater should be installed so that it is not located dire...

Страница 10: ...M2000W DVM2400W Rated Power 500W 1000W 750W 1500W 1000W 2000W 1200W 2400W Rated Voltage 220 240V 50Hz Dimensions mm W460 x D107 x H400 W690 x D107 x H400 W830 x D107 x H400 W950 x D107 x 400 Room Cove...

Страница 11: ...no Electronic heat charge control with room and or outdoor temperature feedback no Fan assisted heat output no Type of heat output room temperature control Single stage heat output and no room tempera...

Страница 12: ...uctions are excluded Consequential costs such as labour charges or damage to surroundings are expressly excluded Contact Us If you experience a problem with this product you should first contact us on...