DS2400T DVB-T2 Signal Analysis Meter Operation Manual
43
SCALE:
After selecting the SCALE parameter, press
or
to choose one scale from 1dB/, 2dB/,
5dB/ and 10dB/.
CENT(CENTER FREQUENCY):
After selecting the CENT
parameter,
you can input the center frequency by the
character/digit keys.
Note:
In Spectrum Scanning function, any frequency
from 5 to 1052MHz can be input.
SPAN:
After selecting the SPAN parameter,
press
or
to adjust the span among 2.5MHz, 6.25MHz,
12.5MHz, 25MHz, 62.5MHz and FullBand.
MAX:
After selecting the MAX-HOLD parameter, if you
select the MAX-HOLD by pressing
or
, the
screen will display both the max value and the
real-time value of each point.
MARKER A:
After selecting the MARKER A parameter,
the red marker A becomes active marker, pressing
or
can move the red marker to the
wanted view point.