4. Modifying an existing Installation
4.3 Changing parameters for Heat Regulation
devilink™ offers 3 types of regulation, which can be set individually for each
room:
Comfort heating
: Constant temperature on the floor in bathrooms and other
rooms where a comfortable warm surface is required. Install the floor sensor
with the devilink™ FT and choose Floor regulation for the room when
carrying out configuration.
Total heating:
Control of room temperature in living rooms etc. Install the
Floor sensor and a devilink™ RS. Choose Combined regulationwhen doing the
configuration on the devilink
™
CC.
No floor sensor:
A floor sensor is not present, and cannot be installed. You
must install a devilink™ RS. Choose Room regulation.
DEVI recommends that a floor sensor is always installed; temperature control
is less accurate without the floor sensor.
If more than one devilink™ FT’s is installed in the same room they must have
the same sensor configuration.
Do not use devilink™ without a floor sensor when the heating element is
installed on or beneath wooden surfaces and other surfaces sensitive to
temperature!