background image

     

SB-2-475-F   Page  7

HAV-500 OR

HAV-511

Adjusting Valve

(HAV-511 SHOWN)

HAV-500 does not have
pressure gage.  Use to
control air usage at gun.

Spray Gun

Lube

SSL-10

(2 oz. bottle)

Compatible with all
paint materials; con-
tains no silicone or
petroleum distillates
to contaminate paint.
MSDS Sheet avail-
able upon request.

ACCESSORIES

TGC-545 Aluminum

TLC-555 (Teflon Lined)

Drip Free Suction Cups

Cups have a unique, two
position valve which permits
selection of either a drip free or
conventional open vent mode.

Automotive Quick Connects

For HVLP Guns (Air)

High Flow Type.

HC-4720 Coupler

1/4" NPT(F)

HC-1166 Stem

1/4" NPT(M)

HC-4419 Stem

1/4" NPT(F)

HC-4719 Coupler

1/4" NPT(M) /

NPS(M)

HARG-510

Air Regulator

Use to maintain nearly
constant outlet
pressure despite
changes in inlet
pressure and

KK-5060 Air Cap

Cleaning Kit

Consists of: 2
brushes, 1 wire pick.
Helps keep air cap
clean and perform-
ing properly.

192218 Scrubs

®

Hand Cleaner Towels

Scrubs

®

  are a pre-

moistened hand
cleaner towel for
painters, body men
and mechanics that
go where you go and
no water is needed.

HAF-507 Whirlwind™

In-Line Air Filter

Removes water, oil, and
debris from the air line.

Joins any single piece
DeVilbiss air cap with
latest version MBC-368,
MSA-1 or GTI-3 retaining
rings.  Helps prevent parts
loss and provides easier
assembly.

JGA-156-K10

Spring Clips

Contains all necessary tip,
hose and nut sizes used on
or with gun.

WR-103 Wrench

Contains six precision tools
designed to effectively clean
all DeVilbiss, Binks, Finishline
and other brand spray guns.

192212 Professional

Spray Gun Cleaning Kit

GTI-415

Air Adjusting Valve

Installs into gun to
enable user to control
and reduce air usage
at the gun. Replaces
JGA-132 plug.

NIOSH-Certified (TC-84A-1623)
for respiratory protection in
atmospheres not immediately
dangerous to life.

MSP-524 Twin Cartridge,

Paint Spray Respirator

PTFE

Содержание PLUS SB-2-475-F

Страница 1: ...strain the material to be sprayedaccordingtothepaintmaufacturer s instructions Strain material through a 60 or 90 mesh screen 1 Fill the suction or pressure feed cup with the material Do not overfill...

Страница 2: ...cessive duration of the activity 5 Tool vibration 6 Repeated pressure on a body part 7 Working in cold temperatures CTD s can also be caused by such activities as sewing golf tennis and bowling to nam...

Страница 3: ...ment Instructions 1 Remove adjusting knob and needle spring from gun 2 Partially withdraw needle from gun body 3 Loosen packing nut and remove 4 Remove old packing 5 Assemble packing nut to needle 6 A...

Страница 4: ...o Part No Description Req 20 Air Valve 1 21 Air Valve Body 1 22 U Cup Seal 1 23 Washer 1 24 Snap Ring 1 25 JGS 449 1 Air Valve Assembly 1 26 P MB 51 Air Inlet Nipple 1 1 4 NPS M 27 Trigger Stud Screw...

Страница 5: ...nt Clean Fluid flow too high for atomization air Material flow exceeds air cap s capacity Spreader adjustment valve set too low Atomizing pressure too low Material too thick Atomization air pressure t...

Страница 6: ...e Air pressure too low Improper thinner being used Material not properly mixed Surface rough oily dirty Tighten tip to 15 20 ft lbs Check distance Normally approx 6 8 Reduce air pressure and check spr...

Страница 7: ...brushes 1wirepick Helps keep air cap cleanandperform ingproperly 192218 Scrubs Hand Cleaner Towels Scrubs are a pre moistened hand cleaner towel for painters body men and mechanics that gowhereyougoan...

Страница 8: ...ck the Yellow Pages under Automotive Body Shop Equipment and Supplies For technical assistance see listing below U S Canada Customer Service Office 1724 Indian Wood Circle Suite J K Maumee OH 43537 To...

Отзывы: