10 - ENG

TROUBLESHOOTING GUIDE (Continued)

CORRECTION

CAUSE

Possible defect in safety valve.

Knocking Noise

Compressor is not supplying
enough air to operate accesso-
ries.

Prolonged excessive use of air.

Decrease amount of air usage.

Hole in hose.

Remove and clean, or replace.

Air leaks.

Tighten fittings.  (See Air Leaks Section of Trou-
bleshooting Guide.)

Motor will not run.

Check valve restricted.

Check and replace.

Check the accessory air requirement.  If it is higher than
the SCFM or pressure supplied by your air compres-
sor, you need a larger compressor.

Compressor is not large enough for air
requirement.

Defective check valve.

Remove and clean, or replace.

Operate safety valve manually by pulling on ring.  If
valve still leaks, it should be replaced.

Air leak from safety valve.

PROBLEM

Motor will start automatically when tank pressure
drops below “cut-in” pressure of pressure switch.

Tank pressure exceeds pressure switch
“cut-in” pressure.

Check for proper gauge wire and cord length.

Wrong gauge wire or length of exten-
sion cord.

Loose electrical connections.

Check wiring connection inside pressure switch and
terminal box area.

Remove and clean, or replace.

Check valve stuck open.

Paint spray on internal motor parts.

Have checked at an Authorized Warranty Service
Center.  Do not operate the compressor in the paint
spray area.  See flammable vapor warning.

Possible defective motor.

Have checked at an Authorized Warranty Service
Center.

1.

Check fuse box for blown fuse and replace, if
necessary.  Reset circuit breaker. Do not use a
fuse or circuit breaker with higher rating than that
specified for your particular branch circuit.

2.

Check for proper fuse.

3.

Check for low voltage conditions and/or proper
extension cord.

4.

Disconnect the other electrical appliances from
circuit or operate the compressor in its own
branch circuit.

Fuse blown, circuit breaker tripped.

Damaged regulator.

Replace regulator.

Regulator knob has continuous
air leak. Regulator will not shut off
at air outlet.

Содержание MG1-UMCCOMP-3

Страница 1: ...ion of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following informati...

Страница 2: ...l be inspected at the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement o If the purchaser does not receive s...

Страница 3: ...MAKE ANY MODIFICATIONS TO THE TANK or its attachments Never attempt to repair a damaged or leaking tank Replace with a new tank The tank is designed to withstand specific operating pressures NEVER MAK...

Страница 4: ...ctly or from a breathing device connected to the compressor WORK IN AN AREA equipped WITH GOOD CROSS VENTILATION Read and FOLLOW THE SAFETY INSTRUCTIONS provided on the label or safety data sheet FOR...

Страница 5: ...ylinder single stage air compressor pump an air tank and associated controls and instruments Thisaircompressorrequiresnooil Nowyoucanenjoyall the benefits of having an air compressor without ever havi...

Страница 6: ...ncoolingsystem Attheheartofthiscoolingsystem is an engineered fan It is perfectly normal for this fan to blowairthroughtheventholesinlargeamounts Youknow that the cooling system is working when air is...

Страница 7: ...lt if the followingbreak ininstructionsare notcloselyfollowed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet...

Страница 8: ...ur com pressor is ready for use 5 Alwaysoperatetheaircompressorinwell ventilated areas freeofgasolineorothersolventvapors Donot operate the compressor near the spray area TOO MUCH AIR PRESSURE CAUSES...

Страница 9: ...air can be heard escaping Check fittings with soapy water solution DO NOT OVER TIGHTEN Airleaksatorinsidecheckvalve Defective or dirty check valve Air leaks in air tank or at air tank welds DO NOT DRI...

Страница 10: ...essureexceedspressureswitch cut in pressure Check for proper gauge wire and cord length Wrong gauge wire or length of exten sion cord Loose electrical connections Check wiring connection inside pressu...

Страница 11: ...11 ENG GENERAL MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR SERVICE NOTES...

Страница 12: ...GENERAL MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR DeVilbiss Air Power Company 213 Industrial Drive Jackson TN 38301 9615 SERVICE NOTES...

Отзывы: