background image

SI-6-41-1-L  (11/2015)

1 / 2

Tamper 

 Resistant

•T-handle must be 
ordered separately.

Air 

Pilot

1

2

3

4

1/8”-27 

NPT(F)

9

15 lb./in. 

(1.6 N-m)

8

6 lb./in. 

(.07 N-m)

14

15

16

18

19

PTFE, (smooth 
gray surface) 
must face 
wetted section

17

20

21

22

23

24

Apply QH-130  
Loctite to threads.

25

26

27

120 lb./in.
13.5 N-m)

1/8-27 
NPT(F) 
Inlet

Non-Circulating 

Port

Circulating Port

120 lb./in.
13.5 N-m)

12

13

11

15 lb./in. 

(1.6 N-m)

8

6

5

7

SERVICE INSTRUCTION

KK-4456 FLUID REGULATOR 

REPAIR KIT

DESCRIPTION

The KK-4456 HGS fluid regulator repair kit 

is recommended for replacement of the 
diaphragm and seating components when 
repairing the regulator. It is designed to 
be used with all HGS regulators.

DISASSEMBLY

 

Shut off and relieve pres-

sure before disconnecting 

hoses from fluid regulator.  

Pressurized parts cause 

a risk of injury to person-

nel if disassembled under 

pressure.

1.  Remove all pressure from regulator.
2.  Remove regulator and clean.

Note

Refer to HGS Fluid Regulator Ser-
vice Bulletin SB-6-403 for general 
service and cleaning procedures.

3.  Remove six cap screws (8).  
4. Remove bottom plug (25) circulating 

regulators; or plug (27) non-circu-
lating regulators.

5.  Remove and discard O ring (24) from 

plug.

6.  Remove stem (23) by inserting a blad-

ed screwdriver into slot and turning 
counterclockwise while holding hex 
nut (14).

7.  Remove and discard upper plate (15), 

gasket  (16),  diaphragm  (17)  and 
PTFE washer (18) from valve stem 
(23). Remove and save flat washer 
(19).

8. Remove and discard PTFE valve seat 

(22) from body (20 or 21).

9.  Clean all parts to remove any trace of 

contaminates.

ASSEMBLY

1. Insert valve seat (22) into body (20 

or  21)  so  that  the  flat  surface  of 

the valve seat is flush with the flat 
surface of  the body.  

2.  Insert stem (23) through seat (22) so 

it extends through body (20 or 21).

3. Install flat washer (19) and PTFE 

washer (18) onto valve stem (23).

Note

PTFE washer (18) must be posi-
tioned  between  the  flat  washer 
(19) and diaphragm (17).

4.  Place diaphragm (17) onto valve stem 

(23) so that threaded portion of stem 
protrudes through diaphragm.

5.  Apply a couple of drops of QH-130 to 

threads of valve stem (23).

6.  Place upper plate (15) over threads of 

stem against diaphragm and secure 
in place with hex nut (14). Torque to 
proper torque specification.

7.  Install gasket (16) and bonnet (10 or 

11) and secure in place with six cap 
screws (8). Torque to proper torque 
specifications.

8. On circulating regulators, Install O 

ring (24) and plug (25); on non-
curculating regulators, install O-ring 
(24) and plug (27); and if equipped, 
install spacer (26). Torque to proper 
torque specification.

9  Reinstall fluid regulator into the system.

PROP 65 WARNING

WARNING: This product 

contains chemicals 

known to the State of 

California to cause 

cancer and birth defects or other 

reproductive harm.

CA PROP

65

Ref. 

No.

Description

Ind. 

Parts 

Req'd.

1

T-handle Kit

2

Adjustment Screw

1

3

Lock

1

4

Guard

1

5

Cap Nut

1

6

Nut

1

7

Allen Set Screw

1

8

Cap Screw

6

9

Connector

1

10

Bonnet

1

11

Bonnet

1

Ref. 

No.

Description

Ind. 

Parts 

Req'd.

12

Adjustment Seat

1

13

Regulator Spring

1

14*

Hex Nut

1

15*

Upper Plate

1

16*

Gasket

1

17*

Diaphragm, PTFE

1

18*

Washer, PTFE

1

19

Flat Washer

1

20

Regulator Body

1

21

Regulator Body

1

22*

Valve Seat, PTFE

1

Ref. 

No.

Description

Ind. 

Parts 

Req'd.

23

Valve Stem

1

24*

O-ring, PTFE

1

25

Plug

1

26

Spacer

1

27

Plug

1

*

QH-130 Loctite

1

•T-handle must be ordered separately.
* These parts are included in the KK-4456  

Regulator Repair Kit.

PARTS LIST