background image

    

 

Ind.

  Ref No.  Replacement   

Parts

  Part No.   

Description 

Req.

 

HAF-404 

Filter Change Indicator 

1

 

 

 

  (not shown)

 1A   

Body 

1

 2   

O-Ring 

1

 

HAF-36 

Filter and O-Ring Kit 

1

 

HAF-11 

Manual Drain 

1

 

HAF-8 

Plastic Bowl  

1

 

HAF-19 

Metal Bowl Guard 

 

HAF-409 

Clamp Ring 

1

SERVICE BULLETIN

SB-6-155-B

Replaces SB-6-155-A

7

3

2

1A

4

HAF-517 - 75 CFM CHARCOAL FILTER

6

5

1 (not shown)

Figure 1 - HAF-517, 75 CFM Charcoal Filter

SPECIFICATIONS

Air Filter:
Air Inlet 

1/2" NPT(F)

Air Outlet 

1/2" NPT(F)

Air Flow Capacity 

75 CFM @ 100 PSI

Maximum Inlet Pressure 

150 PSIG (10.3 Bar)

Maximum Operating Pressure 

150 PSIG (10.3 Bar)

Maximum Temperature 

150° F (65.6°C)

Aerosol Filter 

0.003 ppm/wt.

Particulate Filter 

3.0 micron

PARTS LIST

IMPORTANT: Read and follow all INSTRUCTIONS  and 

SAFETY PRECAUTIONS before installing, operating 

or maintaining this equipment.  Keep this manual for 

future reference.

Risk of explosion or fire.

Improper use can cause personal injury.

• This product is designed and intended for 

use in industrial compressed air systems only.  

Do not use for liquids or gasses other than air.

• Do not use where pressure or temperature 

can exceed rated operating conditions (see 

specifications).

•  Regulated outlet pressure must never be 

set higher than the maximum operating  

pressure of the downstream air tool or  

equipment.  An outlet pressure gauge should 

always be used.

Risk of injury. Do not place unit in service 

without metal bowl guard installed. Filter 

units are sold only with metal bowl guards. 

To minimize the danger of flying fragments 

in the event of plastic bowl failure, guard 

must not be removed. If the unit is in ser-

vice without the metal bowl guard installed, 

manufacturer’s warranties are void and the 

manufacturer assumes no responsibility for 

any resulting loss. If unit has been in service 

and does not have a metal bowl guard, order 

one and install before placing back in service.

Certain compressor oils, cleaning agents and 

solvents may attack the plastic and rubber 

components used in the construction of this 

product. This product should not be used in 

conjunciton with or in the vicinity of these 

materials. Read and follow material labels 

carefully. Please consult DeVilbiss if in doubt.

Отзывы: