7 ENG
Plastic or PVC pipe is not designed for use with
Plastic or PVC pipe is not designed for use with
Plastic or PVC pipe is not designed for use with
Plastic or PVC pipe is not designed for use with
Plastic or PVC pipe is not designed for use with
compressed air. Regardless of its indicated pres-
compressed air. Regardless of its indicated pres-
compressed air. Regardless of its indicated pres-
compressed air. Regardless of its indicated pres-
compressed air. Regardless of its indicated pres-
sure rating, plastic pipe can burst from air pres-
sure rating, plastic pipe can burst from air pres-
sure rating, plastic pipe can burst from air pres-
sure rating, plastic pipe can burst from air pres-
sure rating, plastic pipe can burst from air pres-
sure. Use only metal pipe for air distribution lines.
sure. Use only metal pipe for air distribution lines.
sure. Use only metal pipe for air distribution lines.
sure. Use only metal pipe for air distribution lines.
sure. Use only metal pipe for air distribution lines.
If a pipe line is necessary, use pipe that is the same size as
the air tank outlet. Piping that is too small will restrict the flow
of air. If piping is over 100 feet long, use the next larger size.
Bury underground lines below the frost line and avoid pock-
ets where condensation can gather and freeze. Apply pres-
sure before underground lines are covered to make sure all
pipe joints are free of leaks.
It is recommended that a flexible coupling be installed
between the air discharge valve outlet and main air distribu-
tion line to allow for vibration.
Location of the Air Compressor
Location of the Air Compressor
Location of the Air Compressor
Location of the Air Compressor
Location of the Air Compressor
Locate the air compressor in a clean, dry and well ventilated
area. The air filter must be kept clear of obstructions which
could reduce air flow to the air compressor. The air
compressor should be located at least 12" away from the
wall or other obstructions that will interfere with the flow of
air. The air compressor head and shroud are designed to
allow for proper cooling. If humidity is high, an air filter can
be installed on the air outlet adapter to remove excessive
moisture. Follow the instructions packaged with the air filter
for proper installation.
Lubrication and Oil
This unit needs no lubrication or oiling.
Extension Cords
To avoid voltage drop, power loss, and overheating to the
motor, use extra air hose instead of an extension cord. Low
voltage can cause damage to the motor.
If an extension cord must be used:
• do not use with any permanently mounted air compressor.
• use only a 3-wire extension cord that has a 3-blade
grounding plug and a 3-slot receptacle that will accept
the plug on the extension cord.
• make sure the extension cord is in good condition.
• the extension cord should be no longer than 50 feet.
• the minimum wire size is 12 gauge (AWG). (Wire size
increases as gauge number decreases. 10 AWG and
8 AWG may also be used. DO NOT USE 14 AWG or
16 AWG.)
Voltage and Circuit Protection
Refer to the specification chart for voltage and circuit
protection requirements of your compressor. Use only a fuse
or circuit breaker that is the same rating as the branch circuit
the air compressor is operated on. If the compressor is
connected to a circuit protected by fuses, use only dual
element time delay fuses.
Piping
INST
INST
INST
INST
INSTALLA
ALLA
ALLA
ALLA
ALLATION AND BREAK
TION AND BREAK
TION AND BREAK
TION AND BREAK
TION AND BREAK-IN PROCEDURES
-IN PROCEDURES
-IN PROCEDURES
-IN PROCEDURES
-IN PROCEDURES
Additional Regulators and Controls
Additional Regulators and Controls
Additional Regulators and Controls
Additional Regulators and Controls
Additional Regulators and Controls
Since the air tank pressure is usually greater than that which
is needed, a separate regulator is usually employed to control
the air pressure ahead of any individual air driven device.
Grounding Instructions
RISK OF ELECTRICAL SHOCK! In the event of a short
circuit, grounding reduces the risk of shock by providing
an escape wire for the electric current. This air
compressor must be properly grounded.
IMPROPER GROUNDING CAN RESULT IN ELECTRICAL
SHOCK! ALL GROUNDING SHOULD BE PERFORMED BY
A LICENSED ELECTRICIAN IN ACCORDANCE WITH
NATIONAL AND LOCAL ELECTRICAL CODES!
Make certain that the electrical circuit to which the compressor
is connected provides proper electrical grounding, correct
voltage and adequate fuse protection. The air compressor
can be grounded by the following method:
When hard wiring in an air compressor, use wiring that contains
a bare copper grounding wire. This wire must be connected
to the pressure switch at the grounding location provided.
This is located inside the pressure switch. The other end of
the wire must be connected to a ground at the fuse/circuit
breaker box in accordance with national and local electrical
codes.
If these grounding instructions are not completely understood,
or if in doubt as to whether the compressor is properly
grounded, have the installation checked by an Authorized
Warranty Service Center or a licensed electrician.
Break-in Procedures
Break-in Procedures
Break-in Procedures
Break-in Procedures
Break-in Procedures
This procedure is required:
1.
Before the air compressor is put into service. (Before the
hose is installed.)
2.
When the check valve is replaced.
3.
When a complete compressor pump is replaced.
a. Set the pressure switch lever to the "OFF" position.
b. Plug the power cord into the correct branch circuit
receptacle.
c. Turn the regulator clockwise opening it fully, to
prevent air pressure build-up in the tank.
d. Move the pressure switch lever to "ON/AUTO". The
compressor will start.
e. Run the compressor for 15 minutes. Make sure the
regulator is open and there is no tank pressure build-
up.
f. After 15 minutes, close the regulator by turning it
counterclockwise. The air receiver will fill to cut-out
pressure and the motor will stop. The compressor is
now ready for use.
Serious damage may result if the following
Serious damage may result if the following
Serious damage may result if the following
Serious damage may result if the following
Serious damage may result if the following
break-in instructions are not closely followed.
break-in instructions are not closely followed.
break-in instructions are not closely followed.
break-in instructions are not closely followed.
break-in instructions are not closely followed.