background image

SB-2-616-B     Page 5

Chart 1 For Model Numbers FLG-692, FLG-693 and FLG-694 Spray Guns

Spray Gun

No. on

Ref. No. 2

Ref. No. 3

Fluid Tip Size

Application

Model

Air

Air

Fluid Tip

Supplied

Number

Cap

Cap

with Gun

FLG-692-315

3

FLG-1-3

FLG-302-15K

1.5 mm

HVLP

FLG-693-322

3

FLG-1-3

FLG-302-22K

1.8 mm & 2.2 mm

HVLP

FLG-694-115

1

FLG-1-1

FLG-302-15K

1.5 mm

CONVENTIONAL

Chart 2 FLUID TIPS

Fluid Tip

Fluid Tip

FLUID TIP

Applications

(Ref No. 5)

 Size (in)

 Size (mm)

FLG-302-13K

0.051

1.3

Stains, Lacquers, Basecoats, Clears.

FLG-302-15K

0.059

1.5

General purpose, light to medium viscosity material.

FLG-302-18K

0.07

1.8

Primers and medium viscosity material.

FLG-302-22K

0.086

2.2

Light to medium viscosity material.

Chart-3 HVLP AIR FLOWS (#3 CAP)

Inlet Pressure (PSI)

Air Flow (SCFM)

Cap Pressure (PSI)

15

10

6

19

11.5

8

23

13

10

Содержание FLG-692

Страница 1: ...to split See Spray Gun Guide SB 2 001 which is available upon request for details concerning set up of spray guns To hang the spray gun when not using refer to the Accessories page 8 192219 or GH 407...

Страница 2: ...erials example methylene chloride and 1 1 1 used with these solvents However aluminum is widely Trichlorethylene are not chemically com used in other spray application equipment such as patible with t...

Страница 3: ...assist in removal of the gasket for gasket replacement or when cleaning dried paint from the channel The valve should not be forced past the shoulder which retains it in the lid except for replacement...

Страница 4: ...4 Needle Packing Nut 1 25 FLG 484 Needle Packing Nut Kit 3 Packings 1 Nut 26 FLG 330 Fluid Inlet Fitting 1 27 Adapter 1 2 NPS M 1 28 Nut 3 8 NPS F 1 29 Cam 1 30 TGC 407 1 K3 Drip Free Valve Gasket 1 K...

Страница 5: ...HVLP FLG 694 115 1 FLG 1 1 FLG 302 15K 1 5 mm CONVENTIONAL Chart 2 FLUID TIPS Fluid Tip Fluid Tip FLUID TIP Applications Ref No 5 Size in Size mm FLG 302 13K 0 051 1 3 Stains Lacquers Basecoats Clears...

Страница 6: ...d too far Obstruction in fluid passage Loose or broken fluid tube or fluid inlet nipple Dry or loose fluid needle packing nut Fan adjustment screw not seating properly Air cap retaining ring loose No...

Страница 7: ...slow Hold gun at right angle to work and adapt to proper gun technique Thin sandy coarse finish Gun too far from surface Check distance Normally 6 8 drying before it flows out Too much air pressure Re...

Страница 8: ...um distillates tocontaminatepaint MSDS available upon request Industrial Quick Connects Approved for HVLP Guns Air High Flow Ball and Ring Type HC 4419 1 4 NPS F HC 4699 1 4 NPT M HC 1166 1 4 NPT M HC...

Отзывы: