background image

3 - ENG

RISK OF BURSTING

RISK OF ELECTRIC

SHOCK

RISK OF EXPLOSION OR

FIRE

Air  Tank

TH E  FO L L OWI N G  C O N D I T I O N S
COULD

 lead to a weakening of the tank,

an d 

RESULT  I N  A  VI O L E NT  TA N K

EXPLOSION:

1.

FAILURE TO PROPERLY DRAIN

condensed 

WATER FROM THE

TANK

, causing rust and thinning of

the tank steel.

2.

MODIFICATIONS

 or attempted

repairs 

TO THE TANK

.

3. Unauthorized 

MODIFICATIONS

TO THE PRESSURE SWITCH,
SAFETY VALVE, OR

 any 

OTHER

COMPONENTS WHICH
CONTROL

 tank 

PRESSURE

.

Attachments and Accessories

EXCEEDING THE PRESSURE RATING
OF AIR TOOLS

, spray guns, air operated

accessories, tires 

AND

 other

INFLATABLES CAN CAUSE THEM TO
EXPLODE

 or fly apart, and could result in

serious injury.

Your 

AIR COMPRESSOR

 is powered by

electricity.  Like any other electrically
powered device, 

IF

 it is 

NOT  USED

PR O PE R LY

 it  

MAY 

CA USE

ELECTRICAL  SHOCK.

ELECTRICAL GROUNDING:  FAILURE
TO  PROVIDE  ADEQUATE  GROUND-
I NG   TO   T H IS   PR O D U CT  C O U LD
R ES U LT   IN   S E R I OUS   I N JU RY  OR
DE ATH  FR OM   E L E CTR O C U T I O N.
SEE  GROUNDING  INSTRUCTIONS  IF
APPLICABLE.

It 

is  

n orm al  

for 

E L E CT R I CAL

C ON TA C TS

 w i t h in  t he   mot or  and

pressure switch to 

SPARK

 

WHENEVER

T HE   C O M P RE SS OR   S TA R TS   OR
STOPS

.

DRAIN  TANK  DAILY  OR  AFTER EACH
USE

. If tank develops a leak, replace it

immediately with a new tank or new
compressor outfit.

NEVER

 drill into, weld, or 

MAKE  ANY

MODIFICATIONS  TO  THE  TANK

 or its

attachments.  Never attempt to repair a
damaged or leaking tank.  Replace with
a new tank.

The tank is designed to withstand
specific operating pressures. 

NEVER

MAKE  ADJUSTMENTS  OR  PARTS
SUBSTITUTIONS  TO

 alter the

FACTORY SET

 operating

PRESSURES

.

Follow the equipment manufacturers
recommendation and never exceed the
maximum allowable pressure rating of
attachments. 

NEVER  

USE 

T HE

COMPRESSOR  TO  INFLATE  SMALL
LO W -PRE SSURE  OB J E C TS   SU CH
AS CHILDREN’S  TOYS,  FOOTBALLS,
BASKETBALLS, ETC.

Any 

E L E CT R I CAL WI R I NG  

OR

R E PAI RS

 re q ui red   to  t h is   pro d u ct

S H O U LD  

BE   PE RFO R M ED  

BY

QUALIFIED  SE RVICE  PERSONNEL
OR

 a 

LICENSED ELECTRICIAN

, in

ac cordan ce with  nati onal  and  local
electrical codes.

MAKE  

CE R TAIN

  t hat   the

ELECTRICAL  CIRCUIT

 to which the

compressor is connected 

PROVIDES

PROPER ELECTRICAL  GROUNDING

,

COR R E CT  

V O LTAGE , 

A ND

ADEQUATE  FUSE  PROTECTION

.

Never operate the compressor outdoors
when it is raining.

Always 

OPERATE

 the 

COMPRESSOR

IN

 a well ventilated

 AREA FREE  OF

GASOLINE OR  SOLVENT VAPORS

.

If  sp ray i ng   f la mm a b le   mat e r i a ls,

LOCATE COMPRESSOR

 at least 

20

FEET AWAY FROM  SPRAY AREA

.

STORE FLAMMABLE MATERIALS

 in a

s e cu re   l o ca t i on  

AWAY  

FR O M

COMPRESSOR

.

HAZARD

WHAT CAN HAPPEN

HOW TO PREVENT IT

•  SAVE THESE INSTRUCTIONS •

IMPORTANT SAFETY INSTRUCTIONS

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS
INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING
INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

Содержание FA153

Страница 1: ...essor Part number and description of the item you wish to purchase OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR For Home Use Only SAFETY GUIDELINES 1 WARRANTY 2 WARNING CHART 3 4 GLOSSARY 5...

Страница 2: ...service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company Merchandise sold a...

Страница 3: ...MAKE ANY MODIFICATIONS TO THE TANK or its attachments Never attempt to repair a damaged or leaking tank Replace with a new tank The tank is designed to withstand specific operating pressures NEVER MAK...

Страница 4: ...ctly or from a breathing device connected to the compressor WORK IN AN AREA equipped WITH GOOD CROSS VENTILATION Read and FOLLOW THE SAFETY INSTRUCTIONS provided on the label or safety data sheet FOR...

Страница 5: ...k pressure drops to approximately 100 PSI the motor will restart automatically The low pressure at 1 Set the ON OFF switch to OFF and unplug the cord 2 Reviewthe OperatingProcedures section page9 Be s...

Страница 6: ...will accept the plug on the compressor ingoodcondition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gaugenumberdecreases 12AWG 10AWGand 8 AWG may also be used DO NOT USE 16 OR...

Страница 7: ...lt if the followingbreak ininstructionsare notcloselyfollowed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet...

Страница 8: ...F AUTO lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting Yo...

Страница 9: ...eaks at pressure switch re leasevalve Remove and replace the release valve DO NOT DRILL INTO WELD OR OTHERWISE MODIFY AIR TANK OR IT WILL WEAKEN THE TANK CAN RUPTURE OR EXPLODE TROUBLESHOOTING GUIDE P...

Страница 10: ...Tankpressureexceedspressureswitch cut in pressure Check for proper gauge wire and cord length Wrong gauge wire or length of exten sion cord Loose electrical connections Check wiring connection inside...

Страница 11: ...ANK DRAIN VALVE Not Shown CHECKVALVE Not Shown ISOLATOR DESCRIPTION PART NUMBER REGULATOR CAC 4296 1 TANK PRESSURE GAUGE C GA 345 OUTLET PRESSURE GUAGE C GA 345 SAFETY VALVE TIA 4150 DRAIN VALVE SS 27...

Страница 12: ...ower Company 213 Industrial Drive Jackson TN 38301 9615 WARRANTY This product is covered by the DeVilbiss one year limited warranty The warranty can be found in the General Manual or is available upon...

Отзывы: