DeVilbiss D26563 Скачать руководство пользователя страница 4

4- ENG

D26563

Operation of unit
when damaged,
or with guards or
panels removed.

Removal of guarding could
expose electrically charged
components and result in
electrocution.

Do not operate generator with
protective guarding removed.

Improper
connection of
items to
generator.

Exceeding the load capacity of
the generator by attaching too
many items, or items with very
high load ratings to it could
result in overheating of some
items or their attachment wiring
resulting in fire or electrical
shock.

Attempting to use the unit
when it has been damaged, or
when it is not functioning
normally could result in fire or
electrocution.

Read the load rating chart and
instructions in the Wattage Cal-
culation section. Make sure that
the summation of electrical
loads for all attachments does
not exceed the load rating of the
generator.

Do not operate generator with
mechanical or electrical
problem. Have unit repaired by
an Authorized Service Center.

Operation of
generator in rain,
wet, icy, or
flooded
conditions.

Water is an excellent conductor
of electricity! Water which comes
in contact with electrically
charged components can
transmit electricity to the frame
and other surfaces, resulting in
electrical shock to anyone con-
tacting them.

Operate generator in a clean, dry,
well ventilated area. Make sure
hands are dry before touching
unit.

Use of worn,
damaged, under-
sized or un-
grounded exten-
sion cords.

Use of ungrounded cordsets
could prevent operation of
circuit breakers and result in
electrical shock.

Always use a cordset having a
grounding wire with an
appropriate grounding plug.  DO
NOT use an ungrounded plug.

Use proper size (wire gauge)
cordset for application see chart
in the Assembly section of this
manual.

Contact with worn or damaged
extension cords could result in
electrocution.

Use of undersize extension
cords could result in overheating
of the wires or attached items,
resulting in fire.

Inspect extension cords before
use and replace with new cord if
required.

Placing generator
on or against
highly conductive
surface, such as a
steel walkway or
metal roof.

Place generator on low conduc-
tivity surface such as a concrete
slab.

Accidental leakage of electrical
current could charge conductive
surfaces in contact with the
generator.

RISK OF ELECTROCUTION AND FIRE
(Continued)

HAZARD

WHAT CAN HAPPEN

HOW TO PREVENT IT

ALWAYS operate generator a
minimum of six feet from any
conductive surface.

Содержание D26563

Страница 1: ...com CONSUMER SAFETY INFORMATION 2 SAFETY GUIDELINES DEFINITIONS 2 SAFETY INSTRUCTIONS 2 8 ASSEMBLY 9 11 OPERATION 12 14 MAINTENANCE 15 16 STORAGE 17 18 WATTAGE CALCULATIONS 17 19 TROUBLESHOOTING GUIDE...

Страница 2: ...AL AND SERVICE INFORMATION DO NOT RETURN THIS PRODUCT TO THE RETAILER FOR SERVICE OPTIONS CALL 1 800 888 2468 EXT 2 Please read and follow these instructions for proper use and maintenance Please take...

Страница 3: ...warnings and operating instructions before using RISK OF ELECTROCUTION AND FIRE HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT Attempting to connect generator directly to the electrical system of any build...

Страница 4: ...harged components can transmit electricity to the frame and other surfaces resulting in electrical shock to anyone con tacting them Operate generator in a clean dry well ventilated area Make sure hand...

Страница 5: ...PERATE UNIT INDOORS OR IN ANY CONFINED AREA Materials placed against or near the generator or operating the generator in areas where the temperature exceeds 104 F am bient such as storage rooms or gar...

Страница 6: ...sed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away from area of operat ing unit Gasoline engines produce toxic carbon...

Страница 7: ...surge protector Raising or suspending generators equipped with lift rings improperly Generator could fall causing serious injury or death to you or others Always use proper connecting procedures as de...

Страница 8: ...tempt to operate equipment until you have read this Manual for Safety Operation and Maintenance Instructions Figure 1 8 ENG D26563 HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT HAZARD WHAT CAN HAPPEN HOW T...

Страница 9: ...the National Electrical Code to clarify any needed grounding information Your local electric company or a certified electrician should be able to help you with this information 9 ENG D26563 Grounding...

Страница 10: ...marked battery or let an authorized service center install the battery for you Failure to connect the battery properly can possibly cause bodily injury In addition extensive engine electrical damage...

Страница 11: ...ck into the utility company s system causing possible electrocution of workers who are repairing the electrical lines To avoid back feeding of electricity into utility systems a double throw transfer...

Страница 12: ...the generator will not start until oil is added NOTE The Low Oil Shutdown mechanism is very sensitive You must fill the engine to the full mark on the dipstick to inactivate this safety device BEFORE...

Страница 13: ...4 Grasp handle on rope starter and pull slowly until resistance is felt Let the rope rewind slowly Pull rope with a rapid full arm stroke Let rope rewind slowly Repeat if necessary NOTE IF ENGINE OIL...

Страница 14: ...generator Failure to connect and operate equipment in this sequence can cause damage to equipment and will void the warranty on your generator Follow the wattage calculation table in the Wattage Calc...

Страница 15: ...1 Change oil after first two 2 operating hours and every 50 operating hours thereafter more often if operated in extreme dusty or dirty conditions Note 2 Check oil after 5 hours of operation CUSTOMER...

Страница 16: ...ossible malfunction of the engine GENERATOR Clean the generator as outlined in the Maintenance Section on this manual Check that cooling air slots and openings on generator are open and unobstructed S...

Страница 17: ...ely 2 to 4 times the listed wattage for starting the equipment This initial load only lasts for a few seconds on start up but is very important when figuring your total wattage to be used C Always sta...

Страница 18: ...generator capacity If the nameplate information is not available use the values on the following chart as a guide 3 Remember that the starting and running wattage for resistive loads are the same Exam...

Страница 19: ...TARTING INDUCTIVE LOADS RUN WATTS TIMES X START FACTOR DO NOT CONNECT VOLTAGE SENSITIVE ELECTRONIC EQUIPMENT TV SET COMPUTER ETC DIRECTLY TO YOUR GENERATOR IF YOU USE THE GENERATOR TO POWER SENSITIVE...

Страница 20: ...park plug wire loose 7 Attach wire to spark plug No electrical output 1 Overload 1 Reduce load 2 Faulty cords or equipment 2 Check for damaged bare or frayed wires on equipment Replace Repeated circui...

Страница 21: ...purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT COVER Merchandise sold as r...

Страница 22: ...ngine Do not adjust the throttle or governor to achieve higher performance This will only alter the factory Pre set settings and damage anything connected to the generator Be sure a volt amp surge pro...

Отзывы: