DeVilbiss D26563 Скачать руководство пользователя страница 22

22- ENG

D26563

CALL

1-800-888-2468 

EXT

2

TO FIND A LOCAL AUTHORIZED SERVICE CENTER NEAR YOU FOR REPAIRS

AND SERVICE PART PURCHACES

.

QUICK FACTS

ALWAYS REFER TO THE MANUALS SUPPLIED WITH THIS UNIT

ENGINE

GAS

ENGINE OIL

WATTAGE

WIRING

BATTERY

VOLT REG.

ENGINE

STORAGE

OPERATION

Use clean, fresh gasoline with a minimum 87 octane rating.  Do
not add gasoline during or immediately after use.

Refer to engine owner's manual for oil recommendations.
Most generators are equipped with a low-oil shutdown.  If the oil
is low or if the Generator is not level, the engine will not start.

Make wattage calculations before use.  Refer to general
operator's manual for further instructions.

Contact an electrician for any wiring instructions.  If wiring into a
house, a double-throw transfer switch and a heavy duty cord
set must be used.

Use a standard (12V) lawn and garden battery with a minimum
of 45 A.H. or 210 CCA.

The voltage and frequency are regulated by the rpm's of the
engine.  Do not adjust the throttle or governor to achieve higher
performance.  This will only alter the factory Pre-set settings
and damage anything connected to the generator.

Be sure a volt/amp surge protector is used when sensitive
electronic equipment is used, such as: televisions, computers,
stereos, and etc… The damage of such equipment without the
use of a protector WILL NOT be covered under warranty.

Do not adjust or attempt maintenance without consulting engine
manual or an authorized engine service center.

Add stabilizer to fuel tank and run engine for 5 minutes before
storage.

When in long term storage, operate the generator every 60 days
for at least 10 minutes with a load on it. This will prevent the
loss of residual magnetism that produces the electricity.

Allow the generator to run 5 minutes at no load for the engine
and the gen head to stabilize.

Make sure the adequate size of extension cord is used. Refer to
the Grounding Instructions/Extension Cord section of the
owners manual.

If the generator is operating equipment that is drawing half of
the rated watts it is considered 50% load. Using all of the rated
watts is considered 100% load.

Содержание D26563

Страница 1: ...com CONSUMER SAFETY INFORMATION 2 SAFETY GUIDELINES DEFINITIONS 2 SAFETY INSTRUCTIONS 2 8 ASSEMBLY 9 11 OPERATION 12 14 MAINTENANCE 15 16 STORAGE 17 18 WATTAGE CALCULATIONS 17 19 TROUBLESHOOTING GUIDE...

Страница 2: ...AL AND SERVICE INFORMATION DO NOT RETURN THIS PRODUCT TO THE RETAILER FOR SERVICE OPTIONS CALL 1 800 888 2468 EXT 2 Please read and follow these instructions for proper use and maintenance Please take...

Страница 3: ...warnings and operating instructions before using RISK OF ELECTROCUTION AND FIRE HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT Attempting to connect generator directly to the electrical system of any build...

Страница 4: ...harged components can transmit electricity to the frame and other surfaces resulting in electrical shock to anyone con tacting them Operate generator in a clean dry well ventilated area Make sure hand...

Страница 5: ...PERATE UNIT INDOORS OR IN ANY CONFINED AREA Materials placed against or near the generator or operating the generator in areas where the temperature exceeds 104 F am bient such as storage rooms or gar...

Страница 6: ...sed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away from area of operat ing unit Gasoline engines produce toxic carbon...

Страница 7: ...surge protector Raising or suspending generators equipped with lift rings improperly Generator could fall causing serious injury or death to you or others Always use proper connecting procedures as de...

Страница 8: ...tempt to operate equipment until you have read this Manual for Safety Operation and Maintenance Instructions Figure 1 8 ENG D26563 HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT HAZARD WHAT CAN HAPPEN HOW T...

Страница 9: ...the National Electrical Code to clarify any needed grounding information Your local electric company or a certified electrician should be able to help you with this information 9 ENG D26563 Grounding...

Страница 10: ...marked battery or let an authorized service center install the battery for you Failure to connect the battery properly can possibly cause bodily injury In addition extensive engine electrical damage...

Страница 11: ...ck into the utility company s system causing possible electrocution of workers who are repairing the electrical lines To avoid back feeding of electricity into utility systems a double throw transfer...

Страница 12: ...the generator will not start until oil is added NOTE The Low Oil Shutdown mechanism is very sensitive You must fill the engine to the full mark on the dipstick to inactivate this safety device BEFORE...

Страница 13: ...4 Grasp handle on rope starter and pull slowly until resistance is felt Let the rope rewind slowly Pull rope with a rapid full arm stroke Let rope rewind slowly Repeat if necessary NOTE IF ENGINE OIL...

Страница 14: ...generator Failure to connect and operate equipment in this sequence can cause damage to equipment and will void the warranty on your generator Follow the wattage calculation table in the Wattage Calc...

Страница 15: ...1 Change oil after first two 2 operating hours and every 50 operating hours thereafter more often if operated in extreme dusty or dirty conditions Note 2 Check oil after 5 hours of operation CUSTOMER...

Страница 16: ...ossible malfunction of the engine GENERATOR Clean the generator as outlined in the Maintenance Section on this manual Check that cooling air slots and openings on generator are open and unobstructed S...

Страница 17: ...ely 2 to 4 times the listed wattage for starting the equipment This initial load only lasts for a few seconds on start up but is very important when figuring your total wattage to be used C Always sta...

Страница 18: ...generator capacity If the nameplate information is not available use the values on the following chart as a guide 3 Remember that the starting and running wattage for resistive loads are the same Exam...

Страница 19: ...TARTING INDUCTIVE LOADS RUN WATTS TIMES X START FACTOR DO NOT CONNECT VOLTAGE SENSITIVE ELECTRONIC EQUIPMENT TV SET COMPUTER ETC DIRECTLY TO YOUR GENERATOR IF YOU USE THE GENERATOR TO POWER SENSITIVE...

Страница 20: ...park plug wire loose 7 Attach wire to spark plug No electrical output 1 Overload 1 Reduce load 2 Faulty cords or equipment 2 Check for damaged bare or frayed wires on equipment Replace Repeated circui...

Страница 21: ...purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT COVER Merchandise sold as r...

Страница 22: ...ngine Do not adjust the throttle or governor to achieve higher performance This will only alter the factory Pre set settings and damage anything connected to the generator Be sure a volt amp surge pro...

Отзывы: