background image

Page 4

SB-2-545

INSTALLATION

Important: To ensure that this
equipment reaches you in first
class condition, protective
coatings have been used. Flush
the equipment through with a
suitable solvent before use.

1.

Attach air hose to connector (13).
Recommended hose size 8 mm
bore. The hose must be conductive
and electrical bond from the
spraygun to earth should be checked
with an ohmeter. A resistance of less
than 10

6

Ohms is recommended.

2.

Attach fluid supply hose to Fluid
Inlet (15). 

OPERATION

1.

Mix coating material to manufac-
turers instructions

2.

Turn needle adjusting screw (7)
clockwise to prevent movement. 

3.

Turn spreader valve (5) counter-
clockwise to fully open.

4.

Adjust inlet air pressure (For recom-
mended figures see Specifications)
at the gun inlet with the gun trig-
gered. (pressure gauge attachment
shown under Accessories is recom-
mended for this).

5.

Turn needle adjusting screw counter
clockwise until first thread shows.

6.

Test spray. If the finish is too dry
reduce airflow by reducing air inlet
pressure or by the Airflow Valve
(14). Screw the Adjusting Knob (14)
in to reduce pressure. 

7.

If finish is too wet reduce fluid flow
by turning needle screw (7) clock-
wise or reducing the fluid pressure.
If atomization is too coarse, increase
inlet air pressure. If too fine reduce
inlet pressure.

8.

The pattern size can be reduced by
turning adjusting valve (5) clock-
wise.

9.

Hold gun perpendicular to surface
being sprayed. Arcing or tilting may
result in uneven coating.

10. The recommended spray distance is

150-200 mm (6"-8").

11. Spray edges first. Overlap each

stroke a minimum of 50%. Move gun
at a constant speed.

12. Always turn off air and fluid supply

and relieve pressure when gun is not
in use.

PREVENTATIVE MAINTENANCE

1.

Turn off air and coating supply and
relieve  pressure in the supply lines,
or if using QD system, disconnect
from airline and fluid line.

2.

Remove air cap (1) and clean. If any
of the holes in the cap are blocked
with coating material use a toothpick
to clean. Never use metal wire which
could damage the cap and produce
distorted spray patterns

3.

Ensure the tip of the nozzle (2) is
clean and free from damage. Build
up of dried paint can distort the
spray pattern.

4.

Lubrication – stud/screw (6), needle
(9) and air valve (11) should be oiled
each day.

REPLACEMENT OF PARTS

Nozzle (2) and Needle (9) – 

Remove parts

in the following order: 7, 8, 9, 1 and 2.
Replace any worn or damaged parts and
re-assemble in reverse order.
Recommended tightening torque for
nozzle (2) 9.5-12 Nm (80-100 lbf in). 

Packing – 

Remove parts  7, 8, 9. Unscrew

cartridge (4). Fit new cartridge finger
tight. Re-assemble parts 9, 8, and 7 and
tighten cartridge (4) with spanner suffi-
cient to seal but to allow free movement
of needle. Lubricate with gun oil.

Air Valve Seal Kit (16) – 

(Refer to photos

1 to 28 and fig 2) 

Spreader valve (5) – Caution: 

always

ensure that the valve is in the fully open
position by turning screw fully counter-
clockwise before fitting to body.

SPECIFICATION

Air supply connection:

Universal 1/4" BSP and NPS

Fluid supply connection:

Universal 3/8" BSP and NPS

Maximum static Air inlet pressure:

P

1

= 12 bar (175 psi)

Maximum static Fluid inlet pressure:

P

2

= 15 bar (218 psi)

Nominal gun Air inlet pressure 
with gun triggered: 

1.5 bar (22 psi) 507 HVLP Air Cap
1.1 bar (16 psi) 506 HVLP Air Cap

Maximum Service temperature: 

40°C

Gun Weight:

412 g

MATERIALS OF CONSTRUCTION

Gun body:

Anodized Aluminum

Nozzle:

Stainless Steel

Needle:

Stainless Steel

Fluid Inlet / Fluid Passages:

Stainless Steel / PTFE

Trigger:

Nickel Plated Steel

Содержание Compact COM-PS506B-14-00

Страница 1: ...Service Bulletin SB 2 545 OPERATION MANUAL HVLP PRESSURE FEED SPRAYGUN English Pages 2 9 MANUAL DE OPERACI N COMPACT PISTOLA PULVERIZADORA POR PRESI N HVLP Espa ol P ginas 10 17...

Страница 2: ...is equipment as supplied is NOT suitable for use with Halogenated Hydrocarbons Static Electricity can be generated by fluid and or air passing through hoses by the spraying process and by cleaning non...

Страница 3: ...10 14 18 22 e g 14 1 4 mm 10 Airvalve housing seal SP 612 K 1 11 Spindle 1 12 Trigger SP 617 K 1 13 Connector SP 611 K 1 14 Plug SP 637 1 15 Fluid Inlet Connector and seal SP 636 K 1 16 Air Valve Serv...

Страница 4: ...upply and relieve pressure when gun is not in use PREVENTATIVE MAINTENANCE 1 Turn off air and coating supply and relieve pressure in the supply lines or if using QD system disconnect from airline and...

Страница 5: ...Service Tool SPN 7 engage groove behind the Valve Seat 6 Remove Valve Seat 7 Push out the Front Airvalve Seal with a finger 8 Turn the Gun upside down and let the Seal fall out 9 Fit New Front Seal t...

Страница 6: ...ent 14 Fit new Seal to Service Tool 15 Fit Seal to Housing 10 16 Replace Valve 11 17 Replace Valve Spring and screw in Housing 10 18 Tighten Housing 19 Fit Needle 9 20 Fit Spring 8 and Knob 7 21 Adjus...

Страница 7: ...oose fluid needle packing nut Lubricate or tighten Unable to get round spray Spreader adjustment screw not seating properly Clean or replace Air cap retaining ring loose Tighten Will not spray No air...

Страница 8: ...act Gun TROUBLESHOOTING continued CONDITION CAUSE CORRECTION Thick dimpled finish orange Gun too close to surface Check distance Normally approx 8 peel Too much material coarsely atomized Increase air...

Страница 9: ...nnium 3000 Twin Cartridge Paint Spray Respirator HD 503 SolventSaver Hose Gun Cleaner MPV 60 K3 Air Inlet Swivel Pack of 3 Fits Compact gun only Compatible with DeVilbiss high flow quick disconnects H...

Страница 10: ...uso con Hidrocarburos Halogenados La Electricidad Est tica puede ser generada por el paso de fluido y o aire por los manguitos por el proceso de pulverizaci n y por la limpieza de piezas no conductora...

Страница 11: ...2 K 1 junta 11 V stago 1 12 Gatillo SP 617 K 1 13 Conector SP 611 K 1 14 Tap n SP 637 1 15 Entrada de fluido Conector y junta SP 636 K 1 16 Kit de mantenimiento de la SPK 101 K 1 v lvula de aire 17 Re...

Страница 12: ...una velocidad constante 12 Cierre siempre el suministro de aire y fluido y alivie la presi n cuando la pistola no se est utilizando MANTENIMIENTO PREVENTIVO 1 Cierre el suministro de aire y recubrimi...

Страница 13: ...de la v lvula 6 Retire el asiento de la v lvula 7 Haga salir la junta delantera de la v lvula de aire empu jando con el dedo 8 Ponga la pistola boca abajo y deje que se caiga la junta 9 Instale una j...

Страница 14: ...ta de manten imiento 15 Coloque la junta en el alojamiento 10 16 Vuelva a colocar el husillo 11 17 Vuelva a colocar el muelle de la v lvula y el tornillo en el alojamiento 10 18 Apriete el alojamiento...

Страница 15: ...uido en el tanque Abra el tornillo de ajuste de la aguja de fluido Diluya el material o cambie a alimentaci n por presi n Sobrepulverizaci n excesiva Demasiada presi n de aire de atomizaci n La pistol...

Страница 16: ...OBLEMAS continuaci n CONDICI N CAUSE CORRECCI N Acabado grueso no uniforme como el de una c scara de naranja Verifique la distancia Normalmente aprox 8 pulg Aumente la presi n de aire o disminuya la p...

Страница 17: ...piador de manguito pistola MPV 60 K3 Articulaci n giratoria de entrada de aire paquete de 3 Para pistolas Compact nica mente Compatible con dispositivos de desconexi n r pida de alto flujo DeVilbiss H...

Страница 18: ...Page 18 SB 2 545 NOTES...

Страница 19: ...P gina 19 SB 2 545 NOTAS...

Страница 20: ...S Canada Technical Service Office 195 Internationale Blvd Glendale Heights IL 60139 Toll Free Telephone 1 888 992 4657 U S A and Canada only Toll Free Fax 1 800 368 8401 DeVilbiss Worldwide Sales and...

Отзывы: