2. Connect the thermostat according to the connection
diagram.
IP31
-10T30
D528
Mains
220-240V~
Max. Load
10 (1) A
Sensor
N
L
NTC
N
LOAD
L
LOAD
-5°C
L
By connecting an external timer to the terminal
marked by a moon symbol (and by using for example
the same phase as for the mains power supply), the
thermostat can be set to reduce the temperature by
5ºC during specified periods.
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by us-
ing a separate connector.
Note: Always install the floor sensor in a conduit in the
floor.
DEVIreg™ 528
8
Installation Guide
Содержание DEVIreg 528
Страница 1: ...DEVIreg 528 Electronic Thermostat Installation Guide www DEVI com...