5
Trouble shooting
Short green fl ash
Not included in network
Green fast fl ash
Inclusion in progress
Red fl ash +
for 5 sec.
Inclusion failed
ON
Link test in progress
Red fl ash +
for 5 sec.
Link test failed
ON + Red LED
fl ash every 2½ min.
Low battery level
ON + Red LED
fl ash every 30 sec.
Critical battery level
E5
Floor sensor short circuited
E6
Floor sensor lost
ON
Tamper proof enabled by
Devilink
™
CC
Flash
Limited by Devilink
™
CC
Factory reset a Devilink™ RS:
Take the front cover off . Take out one battery and hold the
ON/OFF/Install button down while reinserting the battery.
Keep holding down the install button until it fl ashes (ap-
prox. 5 sec.)