Instruction Manual
17
Installation of the boiler in the outdoor casing
•
In order to facilitate access to the mounting holes,
open the casing door (A) using the enclosed keys, then
remove the front cover (B).
•
Before mounting the casing on the wall, break through
holes for the flue gas system. Holes are described as:
•
C60/100 - are intended for a coaxial system ø60/
ø100
•
S80 - are intended for a separate system ø80/ø80.
•
Mount the outdoor casing on the wall using the
enclosed expansion bolts (4 pcs.).
Warning:
Different substrates require a specific mounting system.
Before starting the installation of the casing, it is necessary
to check whether the enclosed mounting dowels are
suitable for the installation location.
•
Hang the boiler on a hanger inside the casing.
•
Connection of the boiler to the gas and hydraulic
system, as well as installation of the flue gas exhaust
system and supply of combustion air, should be
performed according to the instruction provided with
the device.
Warning:
In case of installation of the boiler as a type B device - taking
air from the room where it is located, the outdoor casing
has appropriate ventilation to ensure the supply of air in the
appropriate amount.
•
After all necessary installation activities, install the
front cover (B).