FrameMaker Ver5.5E(PC) Di152/Di183 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.07.26
S-14
3-2.
Tech.Rep.Mode Function Setting Procedure
<Procedure>
1. Press the Meter Count key.
2. Press the following keys in this order:
Stop
→
0
→
0
→
Stop
→
0
→
1
3. Enter the code number corresponding to the function to be used from the 10-Key Pad.
Code No.: 0 to 14,20
4. Press the Start Key.
<Exiting the Mode>
• Press the Panel Reset key until the initial screen reappears.
---: Tech.Rep.Mode
---9: Marketing Area Setting
-20: Serial No. Display “Sn”
~
-10: Memory Clear “CLr”
-11: Total Clear “tCL”
-13: ADF Original Glass Check “AdF”
-14: Scanner Drive Check “ccd”
---8: Change Fixed Zoom
-12: ADF Document Passage Test “doc”
Содержание D1531iD
Страница 2: ...FrameMaker Ver5 5E PC Di152 Di183 GENERAL 01 08 27 GENERAL 14413 ...
Страница 3: ......
Страница 5: ......
Страница 15: ......
Страница 16: ...FrameMaker Ver5 5E PC Di152 Di183 MECHANICAL ELECTRICAL 01 09 05 MECHANICAL ELECTRICAL 14413 ...
Страница 17: ......
Страница 73: ......
Страница 84: ...FrameMaker Ver5 5E PC Di152 Di183 DIS REASSEMBLY ADJUSTMENT 01 09 03 DIS REASSEMBLY ADJUSTMENT 10230 ...
Страница 85: ......
Страница 89: ......
Страница 160: ...FrameMaker Ver5 5E PC Di152 Di183 SWITCHES ON PWBs TECH REP SETTINGS 01 07 26 SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Страница 161: ......
Страница 163: ......
Страница 193: ......
Страница 194: ...FrameMaker Ver 5 5E PC Di152 Di183 TROUBLESHOOTING 01 09 04 TROUBLESHOOTING 14390 ...
Страница 195: ......
Страница 259: ......