background image

12                                         

Pictures for illustrating purposes only 

 

STEAM BATH MC REMOTE CONTROL 

Use & Settings

 

Temperature setting point 

Menu scrolling 

Number of lamps 

Perfume intensity 

22°C 

Mo 09:00 

45°C  -                 + 

or 

or 

22°C 

Mo 09:00 

22°C 

Mo 09:00 

   

-                   +

 

Music on or off 

22°C 

Mo 09:00 

   Off 

ou 

or 

or 

or 

Содержание ElectroVap MC2 Series

Страница 1: ...1 Pictures for illustrating purposes only Technical manual Remote control for ElectroVap MC2 Steam Bath ...

Страница 2: ...2 Pictures for illustrating purposes only Description 3 4 Dimensions Installation 5 Electrical connections 6 to 8 Use Settings 9 to 13 STEAM BATH MC REMOTE CONTROL Contents ...

Страница 3: ... REMOTE CONTROL Description 1 2 3 4 5 6 7 1 Steam Production Power On Off Button 2 Date Time Access Setting Button 3 Hammam light Power On Off Button 4 Remote Control On Off Button 5 12 V Power Inlet Jack for optional AC adaptor 6 Navigation Pad 7 OK Button ...

Страница 4: ...control a 12V supply transformer a 8 dry contact control board and a RS485 board This model is capable of powering manually on or off the steam production or automatically thanks to a weekly schedule via terminals 3 4 of the steam bath Offering 8 dry contacts on the 8 contact control board see under the list of possible functions Remote control 230 12V Transformer 3 dry contact board Possible acti...

Страница 5: ... place and mark one of the 4 holes Drill a ø 3 or 4mm hole insert peg and secure the bottom on wall with a screw 1 Make sure that the box is at level and mark up the other 3 holes Take the bottom off wall and drill the holes insert pegs and screws and screw them up Set back the Remote Control front panel and screw back the two lateral screws The installation of the Remote Control is now completed ...

Страница 6: ...75 mm2 maximum flexible wire STEAM BATH 12V TRANSFORMER 230 12V AC ADAPTOR Mains socket 230V N L Terminals on DIN rail of the steam generator Attach the 230 12V transformer inside the electrical compartment of the steam generator with the supplied set of bolts and nuts Connect transformer wires as per attached drawing 61 Red terminal to plug on On Off switch Black terminal to plug on red terminal ...

Страница 7: ...t described under must be made with a 0 75 mm2 maximum flexible wire Clamp the RS485 board onto the DIN rail of the steam generator Connect the RS485 grey ply to the steam generator board Wire the RS485 3 pin connector to the Remote Control board J11 connector with reinforced wire as follows 485 on 2 485 on 1 GND on 3 Remote control board Ref 500650 03 GND reinforced GND reinforced Reinforced wire...

Страница 8: ...33 34 and 36 37 NO contact or terminals 31 32 34 35 and 37 38 NF contact perfume device disinfectant device ventilation or other 1 2 NO Attach the 8 contact board onto the stand offs located under the steam generator main board with M4 8mm long screws Connect the grey plies of the 8 contact board to the connectors X16 X18 of the steam generator main board The 8 contact board makes possible to conn...

Страница 9: ...REMOTE CONTROL Use Settings DISPLAY READING 45 C Mo 00 00 45 C Steam generator in run Hammam lighting on Steam generator on halt Hammam lighting off Perfume on Music option Pre set temperature Auto timer Steam generator on line Steam generator off line Room temperature 45 C ...

Страница 10: ...n arrows of the navigation pad Finally use again the right side arrow for selecting the minute digits Use the up and down arrows for increasing or decreasing the time Press the OK button for validation and press again on button 2 for validation of the day and hour Auto timer Your steam generator can be weekly programmed to work on for a certain time at different time of a day and any day of the we...

Страница 11: ...the down arrow for setting the working time 5 The working time is now illuminated press the OK button 6 For setting the period of time press the up or down arrow 7 For selecting the minutes press the right side arrow 8 For setting the minutes press the up or down arrow 9 Once the working time has been set press the OK button and then press the down arrow The working time is no longer illuminated Y...

Страница 12: ...purposes only STEAM BATH MC REMOTE CONTROL Use Settings Temperature setting point Menu scrolling Number of lamps Perfume intensity 22 C Mo 09 00 45 C or or 22 C Mo 09 00 1 22 C Mo 09 00 Music on or off 22 C Mo 09 00 Off ou or or or ...

Страница 13: ...STEAM BATH MC REMOTE CONTROL Use Settings Option 1 setting 22 C Mo 09 00 Off Opt 1 Option 2 setting 22 C Mo 09 00 Off Opt 2 Option 3 setting 22 C Mo 09 00 Off Opt 3 Remote control nb if several remote controls 22 C Mo 09 00 1 Unit n or or or or ...

Страница 14: ...snil France Export Division tel 33 0 2 35 83 06 44 ou 33 0 2 35 83 03 86 fax 33 0 2 35 85 36 72 Email export devatec com www devatec com devatec reserves the right to change specifications or design of the equipment described in this borchure without prior notice LR 94104 2 ...

Отзывы: