DIMENSIONS AND WEIGHTS
Models 50 and 75
Model Weight
50
150 lbs (68 kg)
75
155 lbs (70 kg)
933 mm
117 mm
1.1/2"
38 mm
429 mm
5 mm
419 mm
25 mm
21 mm
15 1/4"
387 mm
8 7/16"
213 mm
425 mm
6 mm
129 mm
39 mm
175 mm
160 mm
232 mm
59 mm
Страница 1: ...nt in compliance with national and local electrical codes Standard equipment is supplied with NEMA 1 electrical enclosures and is not intended for installation in hazardous environments Disconnect power supply to equipment when per forming any electrical service work 3 Breathing air Air treated by this equipment may not be suitable for breathing without further purification Refer to OSHA standard ...
Страница 2: ...acle of proper voltage NOTE Models 50 and 75 115v only Install plug in receptacle rated for 20 amps Units are supplied with 20 amp plug NOTE Refrigeration system is designed to run continu ously and should NOT be wired to cycle on off with the air compressor I O e a m e Ta Ambient Air Filter Electrical Connection Control Panel Air Inlet Connection Serial Number Tag Drain Connection Air Outlet Conn...
Страница 3: ... 0 62 20 0 57 18 0 51 25 29 0 82 27 0 76 25 0 71 23 0 65 35 41 1 16 38 1 08 35 0 99 32 0 91 Model 50 58 1 64 54 1 53 50 1 42 45 1 27 75 87 2 46 81 2 29 75 2 12 68 1 93 100 116 3 29 108 3 06 100 2 83 91 2 58 125 145 4 12 135 3 82 125 3 54 114 3 23 D Maximum flow capacity 1 For dryers without an aftercooler installed upstream Flow capacity in scfm m 3 min 180 F 82 C inlet temperature 160 F 71 C inle...
Страница 4: ... off compressed air supply to the dryer and depressurize B Remove top panel C Remove two screws holding side panel and remove side panel by sliding upwards D Disconnect drain tube from bulkhead fitting in cabinet base To remove press the plastic collar in toward the fitting while pulling the tube out of the fitting E Remove bowl push bowl up turn bowl 1 8th turn to your left and pull straight down...
Страница 5: ...ssurize B Remove top panel C Remove two screws holding side panel then remove side panel by sliding upwards D Disconnect drain tube from bulkhead fitting in cabinet base To remove press the plastic collar in toward the fitting while pulling the tube out of the fitting E Remove bowl push bowl up turn 1 8th turn to your left and pull bowl straight down F Remove drain tube fitting from bottom of bowl...
Страница 6: ... connection Insulate or heat trace air lines exposed to low ambients or dry air to lower dew point Install separator ahead of dryer B High pressure drop across dryer SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Replace drain mechanism if inoperative Open drain line Check inlet air temperature and pressure flow rate compressor capacity and ambient air temperature See D below Clean inlet air strainer ...
Страница 7: ...um maximum volts 98 127 0 3 1 0 3 1 9 7 9 7 9 7 A L F S p m A d a o L l l u F 0 2 0 2 5 1 5 1 5 1 s p m a e z i S e s u F t i u c r i C h c n a r B Compressor Volts phase Hz 115 1 60 1 1 1 1 1 1 7 6 7 6 7 6 A L R s p m a d a o L d e t a R 0 3 6 0 3 6 0 7 3 0 7 3 0 7 3 A R L s p m a r o t o R d e k c o L 0 5 2 1 0 5 2 1 5 4 6 5 4 6 5 4 6 t u p n i s t t a W Overload Thermal and Current Auto Reset C...
Страница 8: ...low Across Condenser cfm 60 50 Hz 830 690 m3 min 60 50 Hz 23 5 19 5 Electrical Data Unit 208 230 1 60 0 6 1 0 3 2 z H e s a h p C A V 3 5 2 7 8 1 s t l o v m u m i x a m m u m i n i M Full Load Amps FLA 13 3 0 2 s p m a e z i S e s u F t i u c r i C h c n a r B Compressor 0 6 1 0 3 2 8 0 2 z H e s a h p s t l o V Rated Load amps RLA 12 2 Locked Rotor amps LRA 65 8 0 9 3 2 t u p n i s t t a W t e s...
Страница 9: ...ront of Dryer Outside Right Side of Dryer Inside COMPONENT LOCATIONS RC Models 20 thru 125 All Voltages LT SW FPS CT HTS FM OLT M RC Front of Dryer Outside Right Side of Dryer Inside COMPONENT LOCATIONS LEGEND SW On Off Switch OLT Thermal Overload M Compressor Motor RC Run Capacitor HTS High Temperature Switch LT Fault Light FPS Fan Pressure Switch FM Fan Motor TB Terminal Block CT Contactor w 115...
Страница 10: ...EIGHTS Models 20 25 35 Model Weight 20 79 lbs 36 kg 25 80 lbs 36 kg 35 81 lbs 37 kg 718 mm 317 mm 105mm 1 9 16 40mm 5mm 217mm 1 25mm 6mm 257mm 5 1 16 128 mm 257mm 216mm 41mm 130mm 105mm 287mm 1 1 2 38mm 168mm 21mm 327 mm ...
Страница 11: ... DIMENSIONS AND WEIGHTS Models 50 and 75 Model Weight 50 150 lbs 68 kg 75 155 lbs 70 kg 933mm 117mm 1 1 2 38mm 429mm 5mm 419mm 25mm 21mm 151 4 387mm 87 16 213mm 425mm 6mm 129mm 39mm 175mm 160mm 232mm 59mm ...
Страница 12: ...12 DIMENSIONS AND WEIGHTS Models 100 and 125 Model Weight 100 187 lbs 85 kg 125 189 lbs 86 kg 1 1 ...
Страница 13: ...49 Overload Compressor 115 1 60 5925 571 12 5925 571 12 5925 571 12 5925 571 15 5925 571 15 Overload Compressor 208 230 1 60 5925 571 13 5925 571 13 5925 571 13 5925 571 16 5925 571 16 Overload Compressor 220 240 1 50 5925 571 14 5925 571 14 5925 571 14 5925 571 14 5925 571 14 Switch fault light w conn 03 7419 02 03 7419 02 03 7419 02 03 7419 03 03 7419 03 Condenser Fan Fan Motor 115 1 60 6105 226...
Страница 14: ...3 13 5910 103 13 Switch fault light w conn 03 7419 03 03 7419 03 Condenser Fan 9 6 2 2 5 0 1 6 9 6 2 2 5 0 1 6 r o t o M n a F 5 8 7 3 5 0 1 6 5 8 7 3 5 0 1 6 e d a l B n a F Refrigeration System Compressor 230 1 60 4130 106 73 4130 106 73 Compressor 220 240 1 50 4130 106 74 4130 106 74 9 1 2 1 1 0 3 1 4 9 1 2 1 1 0 3 1 4 r e s n e d n o C Hot gas by pass valve 4130 690 22 4130 690 22 2 1 5 6 1 0 ...
Страница 15: ...NOTES 15 ...
Страница 16: ...red portion of the warranty applying to the original product based on the original date of purchase and or date of manufacture as outlined above There is no other expressed warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to one 1 year from date of purchase to the extent permitted by law and any and all implied warranties are excluded ...