65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 40 -
Reboot Device
Pressing Reboot button will initiate a ‘hardware reset’ as if you have switched off and on the
device. The previously applied/saved settings will not be deleted.
Factory Defaults
DB44 could be restored to Factory Defaults from its non-volatile memory. The procedure is
quite simple - Press the ‘Restore Button’ and confirm the procedure.
WARNING:
Before returning DB44 to its factory defaults, all remote users should be informed
that they may cease to communicate with the device.
Session Timeout
Set WEB and SNMP sessions timeout. Please NOTE that during session, the Logger mode is
not active, thus no Alarms are generated.
SNMP MIB File
Press the ‘Download’ button to download the latest available DB44 SNMP MIB file.
NOTE:
The MIB file may vary from one firmware revision to another. Downloading this file
from the device guarantees that you have the proper MIB file.
Содержание DB44